Hisense AC Error
Codes and Troubleshooting
Press the high power
for 4 times in a row and the trouble codes listed below will be displayed.
Hisense
Air Conditioner Error Codes
Error Code
|
Problem
|
0
|
No trouble
|
1
|
Outdoor coil temperature sensor in trouble
|
2
|
Compressor temperature sensor in trouble
|
3
|
Voltage transformer in trouble
|
4
|
Current transformer in trouble
|
5
|
IPM module protection
|
6
|
Over and under-voltage control
|
7
|
Communication trouble
|
8
|
Current overload control
|
9
|
Maximum current control
|
10
|
Communication trouble (between outdoor unit and driver
unit)
|
11
|
Outdoor EEPROM in trouble
|
13
|
Compressor exhaust temperature too high control
|
14
|
Outdoor ambient temperature sensor in trouble
|
15
|
Compressor housing temperature control
|
16
|
Anti-freeze or overload control
|
18
|
DC compressor fails to start
|
19
|
DC compressor out of step
|
33
|
Room temperature sensor in trouble
|
34
|
Indoor coil temperature sensor in trouble
|
35
|
Between wire remote controller and indoor unit
communication trouble
|
36
|
Communication between the indoor and outdoor in trouble
|
37
|
Water overbrimmed the pump
|
The root cause
is may be one of the following:
- It is
normally for protection, When the indoor pipe temperature between
53C<T<63C, the outdoor fan motor will stop running. When the indoor
coil temperature is higher than 63C, the error code will display. After
the indoor pipe temperature is lower than 49C, the air conditioner will
restart normally.
- The
indoor coil temperature sensor is loose;
- The
indoor coil temperature sensor is failure;
- The indoor control board is failure.
Error
Code: E4
Content: When the indoor fan speed is lower than 200 rpm,
the error code will display
The root cause
is may be one of the following:
- There
are something block the indoor fan motor;
- The fan
motor cord connect loose;
- The fan
motor is failure;
- The indoor control board is failure
Error
Code: EA
Content: the error code will display when the communication
between display board and control board have in trouble
The root cause
is may be one of the following:
- The
connection between the display board and control board is loose;
- The
indoor control board is failure.
- The wiring of the display board is failure.
Display of
Error Codes:

When the system stops
running,press the “CHECK” and “↑↓” buttons, “SERVICE” and “00” will
display,”00” is index ,press “∧”and “∨” button to set
the value, the index value is displayed at the timer area .Each index value
shows corresponding content,as follows:
Trouble code: 0
Troubles: No trouble
Trouble code: 1
Troubles: Outdoor coil
temperature sensor in trouble
Possible Cause:
- Outdoor
coil temperature sensor is failure
- Outdoor control board in trouble
Trouble code: 2
Troubles: Compressor
discharge temperature sensor in trouble
Possible Cause:
- Compressor
discharge sensor is failure
- Outdoor control board in trouble
Trouble code: 5
Troubles: IPM
protection
Possible Cause:
- Normal
protection
- Outdoor
IPM control board is failure in the outdoor control board.
- The compressor is failure.
Trouble code: 6
Troubles: Over and
under-voltage control
Possible Cause:
- Voltage
of power supply is abnormal.
- Outdoor control board in trouble.
Trouble code: 8
Troubles: Current
overload control
Possible Cause:
- Normal
protection
- The outdoor control board in trouble.
Trouble code: 9
Troubles: Maximum
current control
Possible Cause:
- Normal
protection
- The compressor is failure
Trouble code: 11
Troubles: Outdoor
EEPROM in trouble
Possible Cause: Outdoor
control board in trouble.
Trouble code: 13
Troubles: Compressor
exhaust temperature too high control
Possible Cause:
- Heat
exchanger and indoor filter were dirty.
- The
refrigeration system was stopt.
- Compressor discharge temperature sensor is
failure.
Trouble code: 14
Troubles: Outdoor ambient
temperature sensor in trouble
Possible Cause:
- Outdoor
ambient temperature sensor is failure
- Outdoor control board in trouble
Trouble code: 15
Troubles: Compressor
housing temperature protection
Possible Cause:
- Compressor
overheat protection sensor is failure
- Outdoor control board in trouble
Trouble code: 16
Troubles: Anti-freeze
or overload control
Possible Cause:
- Indoor
coil temperature sensor is failure.
- Indoor control board in trouble.
Trouble code: 18
Troubles: Compressor
fails to start
Possible Cause:
- Compressor
is failture.
- Outdoor IPM control board is failure in the
outdoor control board.
Trouble code: 33
Troubles: Room
temperature sensor in trouble
Possible Cause:
- Room
temperature sensor is failure
- Indoor control board in trouble