Sharp Air
Conditioner Error Codes
Display Codes
|
Diagnostic Description
|
EE
|
Buttons are locked
|
E0
|
Water pump malffunction
|
E1
|
High pressure protection of compressor
|
E2
|
Indoor anti-frozen of compressor
|
E3
|
Low pressure protection of compressor
|
E4
|
Air discharge high-temperature protection of compressor
|
E5
|
Overload protection of compressor
|
E6
|
Transmit malfunction
|
E8
|
Indoor fan protection
|
E9
|
Water flow protection
|
FF
|
Connected control communications Failure
|
F0
|
Malfunction of indoor environment sensor at air return vent
|
F1
|
Evaporator sensor malfunction
|
F2
|
Condenser sensor malfunction
|
F3
|
Outdoor environment sensor malfunction
|
F4
|
Malfunction of air discharge sensor
|
F5
|
Malfunction of environment sensor on displayer
|
ee
|
Malfunction of outdoor drive memory chip. Outdoor drive
board
|
H3
|
Compressor over load protection. Compressor overload
switch.
|
”ES”
or ”AS”, a sensor has failed
Sharp Air Conditioner Troubleshooting
Sharp Air Conditioner Troubleshooting
Symptom
|
Troubleshooting
|
Air conditioner does not run if attem pt to immediately
restart after a stop.
|
To protect the air conditioner upon immediate restart
after a stop, the microcomputer controller will delay the unit for 3 minutes
before the air conditioner will run.
|
Air conditioner blows out bad smell when it is initially
started.
|
The air conditioner itself has no bad smell. If a bad
smell has been accumulated from the environment, clean the airfilter.
|
You may hear ”Water Flowing” noise
|
When the air conditioner is started, or the compressor is
started or stopped during running or the air conditioner is stopped,
sometimes you may hear fluid gurgling noises. This is not a fault – it is the
sound offlowing refrigerant.
|
Sometimes a thin mist will flow out of the outlet when air
conditioner is running under cooling mode.
|
This might occur when indoor temperature and humidity are
high. This is because the indoor air is quickly cooled down. After a period
of time, the mist will disappear with the decrease of indoor temperature and
humidity.
|
You may hear a slight cracking sound when the air
conditioner is started or stopped.
|
This is the sound of friction caused by expansion and/or
contraction of panel or other parts due to the change of temperature.
|
The unit will not run
|
Has the power been shut down? Has the circuit breaker
device tripped off? Is the Timer correctly used? Have the wiring or
connections been a damaged?P
|
Cooling (Heating) efficiency is not good.
|
Is Temp. setting suitable? Are inlet and outlet vents
obstructed? Are the windows and doors closed? Is the fa n speed_set at low
speed? Is there too much dust accumulated and obstructing the filter?
|
Wireless remote control is not working
|
Check that there is no magnetic or electrical interference
near the main unit that may be affecting the operation of the controller.
|
Water is dripping or leaking from the indoor unit
|
The air humidity is on the high side. Condensing water has
overflowed. The connection of indoor unit drainage pipe has been loosened.
|
Noise from indoor unit
|
Fan or compressor relay is switching on or off. When
defrosting is started or stopped, there is a sound of refrigerant flowing in
the reverse direction.
|
Moisture on air outlet vent
|
If unit is running under high humidity for a long time,
moisture will be condensed on the air outlet grill and may drip off.
|