Shinco AC Error
Codes and Troubleshooting
Display Codes
|
Diagnostic Description
|
EE
|
Buttons are locked
|
E0
|
Water pump malffunction
|
E1
|
High pressure protection of compressor
|
E2
|
Indoor anti-frozen of compressor
|
E3
|
Low pressure protection of compressor
|
E4
|
Air discharge high-temperature protection of compressor
|
E5
|
Overload protection of compressor
|
E6
|
Transmit malfunction
|
E8
|
Indoor fan protection
|
E9
|
Water flow protection
|
FF
|
Connected control communications Failure
|
F0
|
Malfunction of indoor environment sensor at air return
vent
|
F1
|
Evaporator sensor malfunction
|
F2
|
Condenser sensor malfunction
|
F3
|
Outdoor environment sensor malfunction
|
F4
|
Malfunction of air discharge sensor
|
F5
|
Malfunction of environment sensor on displayer
|
ee
|
Malfunction of outdoor drive memory chip. Outdoor drive
board
|
H3
|
Compressor over load protection. Compressor overload
switch.
|
How to Fix?
Fault code display;
KFR-25GWZ/BM –
KFR-35GWZ/BM Models;
Code: EP
Fault: Indoor Unit
Don’t Match Outdoor Unit
Check Point: Check
If The Indoor Unit Match Outdoor Uint
Count
Measure: Change Wrong Unit
Code: E0
Fault: Outdoor
Discharge Pipe Sensor Fault
Check Point:
- Checkthe
Value Of Sensor
- Outdoor Power Board Is Fault(check
capicator)
Count Measure:
- Change
Sensor
- Change Power Board
Code: E4
Fault: Communication
Fault Between Indoor Unit And Outdoor Unit
Check Point:
- Check
if the connecting wiring is connect well
- Test
the voltage value between L4 and S, if it ‘s change regularly, the singal
transfering between indoor and outdoor unit is good, when it‘s no change
if value is below 14v, the indoor pcb board is fault, change it. if value
is over 14v, the outdoor pcb is faulty
- Check if there is led flashing on the outdoor
pcb if there is no flashing, check voltage value from power board to pfc
board, between acl and can on pfc board if it’s not 220v, change power
board if it’s 220v, change pfc board
Count Measure:
- Fix
The Wiring Again
- Change Relate Pcb Board
Shinco AC Error Codes and Troubleshooting
Code: EA
Fault: Compressor
Driver Board Is Faulty
Check Point: Check
Outdoor Driver Board
Count
Measure: Change Driver Board
Code: E6
Fault:
- Ourdoor
Air Sensor Is Faulty
- Outdoor Pipe Sensor Is Fault
Check Point:
- Check
The Sendor Value
- Power Board Is Faul
Count Measure:
- Change
Sensor
- Change Power Baord
Code: E1
Fault: Indoor Air
Sensor Is Faulty
Check Point:
- Check
The Sensor Value
- Indoor Board Is Fault
Count Measure:
- Change
Sendor
- Change Indoor Board
Code: E2
Fault: Indoor Pipe
Sensor Is Faulty
Check Point:
- Check
The Sensor Value
- Indoor Board Is Fault
Count Measure:
- Change
Sendor
- Change Indoor Board
Code: E8
Fault: Power Board
Is Fault
Check
Point: Outdoor Power Board Is Fault
Count
Measure: Change The Power Board
Code: E9
Fault: Power Board
Is Fault
Check
Point: Outdoor Power Board Is Fault
Count
Measure: Change The Power Board
Code: E5
Fault: Driver
Board Is Fault
Check
Point: Driver Board Is Fault
Count
Measure: Driver Board Is Fault
Code: EC
Fault: Oudoor
Communication Faulty
Check Point: Check
If Wirings Between Power Board And Driver Board Are Connected Well
Count Measure: Fix
The Wiring Between Power Board And Driver Board
Code: E3
Fault: Indoor Motor Is
Fault
Check Point:
- Indoor
Motor Or Indoor Motor Capacitor Is Fault
- Inner
Wiring Don’t Connect Well
- Indoor
Pcb Is Fault
- Indoor Motor Is Blocked
Count Measure:
- Change
Motor Or Capacitor
- Fix
The Wirings
- Change
Indoor Pcb
- Remove The Blocking
Code: EE
Fault: Indoor Pcb
Baord Is Faulty
Check
Point: Indoor Pcb Baord Is Faulty
Count
Measure: Indoor Pcb Baord Is Faulty
Code: P1
Fault: Outdoor
Discharge Temp Is Too High
Check Point:
- Check
If The Outlet Is Blocked Or The Condensor Is Dirty
- Check
The Outdoor Motor Work Normally
- Check If The Refrigerant Is Charged Too Much
Count Measure:
- Remove
Obstacle Around Outdoor Unit Or Wash The Condenser
- Change
Outdoor Motor Or Motor Capacitor
- Regulate The Quantity Of Refrigerant
Code: P7
Fault: Driver
Board Protection
Check Point:
- Check
If The Refrigerant Is Charged Too Much
- Check
If The Compressor Is Blocked
- Ipm Mold Is Fault
Count Measure:
- Regulate
The Quantity Of Refrigerant
- Change
Compressor
- Change Ipm Mold
Code: P3
Fault: The Voltage
Is Not Stable
Check Point: Check
The Power Supply
Count
Measure: Restart The Air Conditioner
Code: P2
Fault: Electric
Current Is Too High
Check Point:
- Check
If The Refrigerant Is Charged Too Much
- Check
If The Voltage Is Too Low, Power Wringis Too Thin Or Too Long Or Contact
Badly
- Check
If The Outlet Is Blocked Or The Condensor Is Dirty
- Check The Outdoor Motor Work Normally
Count Measure:
- Regulate The Quantity Of Refrigerant
Updating Power Supply, Chang Power Wiring
Remove Obstacle Around Outdoor Unit Or Wash The Condenser
Change Outdoor Motor Or Motor Capacitor