Shinco AC Error Codes and Troubleshooting


Shinco AC Error Codes and Troubleshooting

Display Codes
Diagnostic Description
EE
Buttons are locked
E0
Water pump malffunction
E1
High pressure protection of compressor
E2
Indoor anti-frozen of compressor
E3
Low pressure protection of compressor
E4
Air discharge high-temperature protection of compressor
E5
Overload protection of compressor
E6
Transmit malfunction
E8
Indoor fan protection
E9
Water flow protection
FF
Connected control communications Failure
F0
Malfunction of indoor environment sensor at air return vent
F1
Evaporator sensor malfunction
F2
Condenser sensor malfunction
F3
Outdoor environment sensor malfunction
F4
Malfunction of air discharge sensor
F5
Malfunction of environment sensor on displayer
ee
Malfunction of outdoor drive memory chip. Outdoor drive board
H3
Compressor over load protection. Compressor overload switch.
How to Fix?
Fault code display;
KFR-25GWZ/BM – KFR-35GWZ/BM Models;

Code: EP 
Fault: Indoor Unit Don’t Match Outdoor Unit
Check Point: Check If The Indoor Unit Match Outdoor Uint
Count Measure: Change Wrong Unit
Code: E0 
Fault: Outdoor Discharge Pipe Sensor Fault
Check Point:
  1. Checkthe Value Of Sensor
  2. Outdoor Power Board Is Faultcheck capicator
Count Measure:
  1. Change Sensor
  2. Change Power Board
Code: E4 
Fault: Communication Fault Between Indoor Unit And Outdoor Unit
Check Point:


  1. Check if the connecting wiring is connect well
  2. Test the voltage value between L4 and S, if it ‘s change regularly, the singal transfering between indoor and outdoor unit is good, when it‘s no change if value is below 14v, the indoor pcb board is fault, change it. if value is over 14v, the outdoor pcb is faulty
  3. Check if there is led flashing on the outdoor pcb if there is no flashing, check voltage value from power board to pfc board, between acl and can on pfc board if it’s not 220v, change power board if it’s 220v, change pfc board
Count Measure:
  1. Fix The Wiring Again
  2. Change Relate Pcb Board
Shinco AC Error Codes and Troubleshooting
Code: EA
Fault: Compressor Driver Board Is Faulty
Check Point: Check Outdoor Driver Board
Count Measure: Change Driver Board
Code: E6
Fault:
  1. Ourdoor Air Sensor Is Faulty
  2. Outdoor Pipe Sensor Is Fault
Check Point:
  1. Check The Sendor Value
  2. Power Board Is Faul
Count Measure:
  1. Change Sensor
  2. Change Power Baord
Code: E1
Fault: Indoor Air Sensor Is Faulty
Check Point:
  1. Check The Sensor Value
  2. Indoor Board Is Fault
Count Measure:
  1. Change Sendor
  2. Change Indoor Board
Code: E2 
Fault: Indoor Pipe Sensor Is Faulty


Check Point:
  1. Check The Sensor Value
  2. Indoor Board Is Fault
Count Measure:
  1. Change Sendor
  2. Change Indoor Board
Code: E8 
Fault: Power Board Is Fault
Check Point: Outdoor Power Board Is Fault
Count Measure: Change The Power Board
CodeE9
Fault: Power Board Is Fault
Check Point: Outdoor Power Board Is Fault
Count Measure: Change The Power Board
Code: E5
Fault: Driver Board Is Fault
Check Point: Driver Board Is Fault
Count Measure: Driver Board Is Fault
Code: EC 
Fault: Oudoor Communication Faulty
Check Point: Check If Wirings Between Power Board And Driver Board Are Connected Well
Count Measure: Fix The Wiring Between Power Board And Driver Board
Code: E3
Fault: Indoor Motor Is Fault
Check Point:
  1. Indoor Motor Or Indoor Motor Capacitor Is Fault
  2. Inner Wiring Don’t Connect Well
  3. Indoor Pcb Is Fault
  4. Indoor Motor Is Blocked
Count Measure:
  1. Change Motor Or Capacitor
  2. Fix The Wirings
  3. Change Indoor Pcb
  4. Remove The Blocking
Code: EE
Fault: Indoor Pcb Baord Is Faulty
Check Point: Indoor Pcb Baord Is Faulty


Count Measure: Indoor Pcb Baord Is Faulty
Code: P1 
Fault: Outdoor Discharge Temp Is Too High
Check Point:
  1. Check If The Outlet Is Blocked Or The Condensor Is Dirty
  2. Check The Outdoor Motor Work Normally
  3. Check If The Refrigerant Is Charged Too Much
Count Measure:
  1. Remove Obstacle Around Outdoor Unit Or Wash The Condenser
  2. Change Outdoor Motor Or Motor Capacitor
  3. Regulate The Quantity Of Refrigerant
Code: P7
Fault: Driver Board Protection
Check Point:
  1. Check If The Refrigerant Is Charged Too Much
  2. Check If The Compressor Is Blocked
  3. Ipm Mold Is Fault
Count Measure:
  1. Regulate The Quantity Of Refrigerant
  2. Change Compressor
  3. Change Ipm Mold
Code: P3 
Fault: The Voltage Is Not Stable
Check Point: Check The Power Supply
Count Measure: Restart The Air Conditioner
Code: P2 
Fault: Electric Current Is Too High
Check Point:
  1. Check If The Refrigerant Is Charged Too Much
  2. Check If The Voltage Is Too Low, Power Wringis Too Thin Or Too Long Or Contact Badly
  3. Check If The Outlet Is Blocked Or The Condensor Is Dirty
  4. Check The Outdoor Motor Work Normally
Count Measure:
  1. Regulate The Quantity Of Refrigerant
    Updating Power Supply, Chang Power Wiring
    Remove Obstacle Around Outdoor Unit Or Wash The Condenser
    Change Outdoor Motor Or Motor Capacitor