My Blog List

TCL Air Conditioner Error Codes

TCL Air Conditioner Error Codes


Protection and Fault Codes;
TCL Air Conditioner Error Codes
Error Code
Meaning
E0
Indoor/outdoor communication fault
EC
Outdoor communication fault
E1
Room temperature sensor (IRT)
E2
Indoor pipe (coil) temperature sensor (IPT)
E3
Outdoor pipe (coil) temperature sensor (OPT)
E4
System abnormal
E5
Model configuration wrong
E6
Indoor fan motor fault
E7
Outdoor temperature sensor
E8
Exhaust temperature sensor
E9
Intelligent power module of drive and module fault
EF
Outdoor fan motor fault (DC Motor)
EA
Current sensor fault
EE
EEPROM fault
EP
Temperature switch fault (on top of the compressor)
EU
Voltage sensor fault
EH
Intake temperature sensor
P1
Overvoltage / undervoltage protection
P2
Overcurrent protection
P4
Exhaust overtemperature protection
P5
Subcooling protection under cooling mode
P6
Overheating protection under cooling mode
P7
Overheating protection under heating mode
P8
Outdoor overtemperature / undertemperature protection
P9
Drive protection (software control )
P0
Module protection (hardware control)
Protection and Failure Display;
  • When protection display is available, controller will show error code, digital LED shows error code and setting temperature by turns.
  • If there is more than one failure, it will show at first that in front of the error list.
  • Protection display function can be selected in hardware, and the default don’t display;
  • To insure of in and out communist is credibility, the failures relate to outdoor unit will remain failure state for 2 minutes max after recovered.
  • In all failures, only sensor failures don’t have to repower to cancel.
Error list;


TCL AC Error List
Protection display code list: 


TCL AC Display Code List
Outdoor failure display;
There is a LED on outdoor power board, when compressor is running; it is normally light; when no feedback of signal to power board from compressor, it will wink by lighting 1s and going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go out 3s for a cycle to indicate failures.

TCL AC Remote Controller
The failure list is the follow:
Wink time/Failure
1: IPM protection
2: higher or lower voltage
3: Over current
4: Discharge temperature too high
5: Outdoor coil temperature too high
6: Drive abnormity
7: Communication abnormity with indoor unit
8: Compressor over heat(switch on top of compressor)
9: Outdoor air temperature sensor failure
10: Outdoor coil temperature sensor failure
11: Outdoor discharge pipe temperature sensor failure
12: Voltage sensor failure
13: Current sensor failure
14: IPM abnormity
15: Outdoor communication abnormity
16: DC fan motor no feedback
17: defrosting



voltas AC unlock passwords