Frigidaire Portable Air Conditioner Error Codes
When you turn on the unit, the louver will swing and stop at a certain
angle. You can press the SWING button to let the louver swing automatically.
Press the SWING button again while you want the louver stop at desired angle.
CHECK FILTER FEATURE:This feature is a reminder to clean the Air Filter (See
Care and Cleaning) for more efficient operation. The LED (light) which above
the “Filter” button will illuminate after 250 hours of operation. To
reset after cleaning the filter, press the “Filter” button and the light will
go off.EA: If the display reads “EA” , the room temperature sensor has failed. Contact your Authorized
ES: If the display reads “ES” , the evaporator temperature sensor has failed. Contact your Authorized
E4: If the display reads “E4” , the display panel communication has failed. Contact your Authorized
P1: If the display reads “P1” , bottom tray is full. Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Restart the machine until the “P1” symbol disappears. If error repeats, call for service.
DRAINAGE:
During the dehumidifying mode, you will need a garden hose (sold separately) to drain the condensate from the unit.
Remove the rubber stopper from the hose connector, then screw on a garden hose to the connector as shown on fig 25.
The hose may then:
A. Discharge into a drain that is lower than the unit.
B. Be connected to a condensate pump (sold separately).
REMOTE CONTROL STORAGE :
The door on side of the unit is for storing the remote, to open press it as shown in Fig. 26, to close simply push it back into position.