My Blog List

Haier Air Conditioner Fault Codes


Haier Air Conditioner Fault Codes
Model HDU-24CA03/M(R1) HDU-28CA03/M(R1) HDU-36CA03/M(R1) HDU-42CA03/M(R1)
Model HSU-09/12HVA103/R2(DB)FOR Eorope

NO.
Error Code
Fault Description
Fault unit
1
E7
Communication fault
Indoor unit
2
E1
Room temperature sensor fault
Indoor unit
3
E2
Heat-exchange sensor fault
Indoor unit
4
E4
Indoor EEPROM error
Indoor unit
5
E14
Indoor fan motor malfunction
Indoor unit
6
F12
Outdoor EEPROM fault
Outdoor unit
7
F1
The protection error of IPM
Outdoor unit
8
F22
Overcurrent  protection of  AC electricity  for  the outdoor model
Outdoor unit
9
F3
Communication fault between the IPM and outdoor PCB
Outdoor unit
10
F19
Power voltage too high or too low
Outdoor unit
11
F4
Overheat protection error of exhaust temperature sensor
Outdoor unit
12
F21
Defrost temperature sensor fault
Outdoor unit
13
F7
Suction temperature sensor fault
Outdoor unit
14
F6
 Ambient temperature sensor failure
Outdoor unit
15
F25
Discharge temperature sensor fault
Outdoor unit
16
F11
deviate from the normal  for the compressor
Outdoor unit
17
F28
Loop  of  the station detect error
Outdoor unit
18
F2
Overcurrent of the compressor
Outdoor unit
19
F23
Overcurrent protection for single-phase of the compressor
Outdoor unit
20
E9
High work-intense protection
Outdoor unit
21
F66
Ambient temperature sensor fault


Code = E0
Flash time of
compressor
running
indicate lamp = 10
Trouble contents (old) = drainage system trouble
Trouble contents (new) = drainage system trouble
Code = E1
Flash time of
compressor
running
indicate lamp = 1
Trouble contents (old) = indoor temperature sensor broken
Trouble contents (new) = indoor temperature sensor broken
Code = E2
Flash time of
compressor
running
indicate lamp = 2
Trouble contents (old) = indoor coil temperature sensor broken
Trouble contents (new) = indoor coil temperature sensor broken
Code = E3
Flash time of
compressor
running
indicate lamp = 3
Trouble contents (old) = outdoor temperature sensor broken
Trouble contents (new) = outdoor temperature sensor broken
Code = E4
Flash time of
compressor
running
indicate lamp = 4
Trouble contents (old) = outdoor coil temperature sensor broken
Trouble contents (new) = outdoor coil temperature sensor broken
ADVERTISEMENT


Code = E5
Flash time of
compressor
running
indicate lamp = 5
Trouble contents (old) = over current protect limit
Trouble contents (new) = over current protect limit
Code = E6
Flash time of
compressor
running
indicate lamp = 6
Trouble contents (old) = pressure protect
Trouble contents (new) = pressure protect
Code = E7
Flash time of
compressor
running
indicate lamp = 7
Trouble contents (old) = communication trouble between wired remote controller and indoor unit.
Trouble contents (new) = three phase protect
Code = E8
Flash time of
compressor
running
indicate lamp = 8
Trouble contents (old) = communication trouble between indoor and outdoor unit.
Trouble contents (new) = Communication trouble between wired remote controller and indoor unit
Code = E9
Flash time of
compressor
running
indicate lamp = 9
Trouble contents (old) = three phase protect
Trouble contents (new) = communication trouble between indoor and outdoor unit
HSU-09/12HVA103/R2(DB)FOR Eorope
Error Codes and Description indoor and outdoor display(1)
Indoor and Outdoor = E7
Indoor Malfunction =
Code indication
Indoor =
Outdoor (LED1 flash times) = 15

Description = Communication fault between indoor and outdoor units
Indoor and Outdoor =
Indoor Malfunction = E1
Code indication
Indoor =
Outdoor (LED1 flash times) =

Description = Room temperature sensor failure
Indoor and Outdoor =
Indoor Malfunction = E2
Code indication
Indoor =
Outdoor (LED1 flash times) =

Description = Heat-exchange sensor failure
Indoor and Outdoor =
Indoor Malfunction = E4
Code indication
Indoor =
Outdoor (LED1 flash times) =

Description = Indoor EEPROM error
Indoor and Outdoor =
Indoor Malfunction = E14
Code indication
Indoor =
Outdoor (LED1 flash times) =

Description = Indoor fan motor malfunction
Indoor and Outdoor =
Indoor Malfunction = E9
Code indication
Indoor =
Outdoor (LED1 flash times) =

Description = High work-E9 intense protection
Error Codes and Description indoor and outdoor display(2)
Outdoor Malfunction
Code Indication
Indoor = F12
Outdoor (LED1 flash times) = 1

Description = Outdoor EEPROM error
Outdoor Malfunction
Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 2

Description = The protection of IPM
Outdoor Malfunction
Code Indication
Indoor = F22
Outdoor (LED1 flash times) = 3
Description = Over current protection of AC electricity for the outdoor model

Outdoor Malfunction
Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 4
Description = Communication fault between the IPM and outdoor PCB

Outdoor Malfunction
Code Indication
Indoor =
Outdoor (LED1 flash times) = 5
Description = Over pressure or Overheat protection for the compressor
Outdoor Malfunction

Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 6
Description = Power voltage is too high or low

Outdoor Malfunction
Code Indication
Indoor = F4
Outdoor (LED1 flash times) = 8
Description = Overheat protection for exhaust temperature

Outdoor Malfunction
Code Indication
Indoor =
Outdoor (LED1 flash times) = 9
Description = outdoor fan motor malfunction

Outdoor Malfunction
Code Indication
Indoor = F21
Outdoor (LED1 flash times) = 10
Description = Frost-removing temperature sensor failure

Outdoor Malfunction
Code Indication
Indoor = F6
Outdoor (LED1 flash times) = 12
Description = Ambient temperature sensor failure

Outdoor Malfunction
Code Indication
Indoor = F25
Outdoor (LED1 flash times) = 13
Description = Exhaust temperature sensor failure

Outdoor Malfunction
Code Indication
Indoor =
Outdoor (LED1 flash times) = 18
Description = deviate from the normal for the compressor

Outdoor Malfunction
Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 19
Description = Loop of the station detect error

Outdoor Malfunction
Code Indication
Indoor = – – –
Outdoor (LED1 flash times) = 24
Description = Over current of the compressor

Outdoor Malfunction
Code Indication
Indoor = – – –
Outdoor (LED1 flash times) = 25
Description = Over current protection for single-past of the compressor


voltas AC unlock passwords