 Samsung AC & Air conditioner Error Codes:                             Complete List



CodePossible Cause
ChProhibit starting during operation of the Crack case heater
E108Error due to repeated communication address
E121Error on room temperature sensor of indoor unit (Short or Open)
E122Error on EVA IN sensor of indoor unit (Short or Open)
E123Error on EVA OUT sensor of indoor unit (Short or Open)
E124Communication error sends from indoor unit
E128Indoor unit EVA IN sensor breakaway
E129Indoor unit EVA OUT sensor breakaway
E131Indoor unit heater sensor error
E151Indoor unit EEV open failure(When 2* detection)
E152Indoor unit EEV close failure(When 2“ detection)
E153Indoor unit floating S/V error(When 2“ detection)
E154Indoor unit fan error
E162Outdoor unit EEPROM error
E198Error on thermal fuse of indoor unit (Open)
E201Communication error between indoor unit and outdoor unit (Pre tracking failure or when actual number of indoor units are different from the indoor unit quantity setting on the outdoor unit) Error due to communication tracking failure after initial power supply (The error occurs with the failure regardless of the number of devices)
E202Communication error between indoor and outdoor unit (When not received in every room after completing the tracking)
E203Communication error between outdoor unit inv - main micom (For PF #4~#6 controller, error will be determined from the time when compressor turns on)
E221Error on outdoor temperature sensor (Short or Open)
E231Error on outdoor COND OUT sensor (Short or Open)
E241COND OUT sensor breakaway
E251Digital comp.1 discharge temperature sensor(Short or Open)
E256Fixed comp.1 discharge temperature sensor(Short or Open)
E257Fixed comp.2 discharge temperature sensor(Short or Open)
E258Fixed comp.3 discharge temperature sensor(Short or Open)
E262Fixed compl Discharge temperature sensor breakaway
E263Fixed comp2 Discharge temperature sensor breakaway
E264Fixed comp3 Discharge temperature sensor breakaway
E265Digital compl Sump temperature sensor breakaway. Fixed compl Sump temperature sensor breakaway
E267Fixed comp2 Sump temperature sensor breakaway
E268Fixed comp3 Sump temperature sensor breakaway
E269Suction temperature sensor breakaway
E271Comp.1 Sump temperature sensor(Short or Open)
E291High pressure sensor(Short or Open)
E296Low pressure sensor(Short or Open)
E307Oil balance sensorl (Short or Open)
E308Suction sensor(Short or Open)
E311Double pipe sensor(Short or Open)
E320Error on OLP sensor (Short or Open)
E403Compressor down due to freeze protection control
E404System stop due to overload protection control
E407Comp, down by high pressure
E410Comp, down by low pressure
E413Comp, down by the sump protection control
E416Comp, down by the discharge temperature sensor
E422Blockage detected on high pressure pipe
E425Reverse phase or open phase
E428Comp down by compression ratio control
E431Equal oil valve 1 self diagnosis
E440Heating operation restricted at outdoor temperature overheating value (default: 30 °C)
E441Cooling operation restricted at outdoor temperature below cool value (default 0°Q
E442Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15°C
E443Start prohibition by refrigerant pressure error
E452Instant power off error
E453Fan motor hifi temperature error
E454Fan motor RPM error
E455Fan motor IPM high temperature error
E456Fan motor over current error
E457Fan motor reverse rotation error
E458Fan speed error
E461Error due to operation failure of inverter compressor
E461CTJow current
E462System stop due to full current control
E463System stop due to OLP temperature control
E464System stop due to DC Peak
E465Compressor overload prevention
E466DC-Link voltage under/over error
E467Error due to abnormal rotation of the compressor or unconnected wire of compressor
E468Error on current sensor (Short or Open)
E469Error on DC-Link voltage sensor (Short or Open)
E470Outdoor unit EEPROM Read/Write error (Option)
E471Outdoor unit EEPROM Read/Write error (H/W)
E472AC Line Zero Cross Signal out
E473Comp Lock error
E474Error on IPM Heat Sink sensor of inverter 1 (Short or Open)
E475Error of inverter fan 2
E484PFC Overload (Over current) Error
E485Error on input current sensor of inverter 1 (Short or Open)
E500IPM over heat error on inverter 1
E508Smart install is not installed
E554Gas leak detected
E556Error due to mismatching capacity of indoor and outdoor unit
E557DPM remote controller option error
E560Switch option setting error(rvot applied)
E590Inverter EEPROM Checksum error
E660Error of inverter Boot Code
P701Indoor unit floating S/V error(When 1“ detection)
P702Indoor unit EEV close failure(When 1“ detection)
P703Indoor unit EEV open failure(When 1“ detection)

CodePossible CauseSolution
* 1Indoor unit thermistor sensor errorIndoor unit thermistor sensor
PCB of the Indoor unit
* 5Indoor unit pipe thermistor sensor errorIndoor unit pipe thermistor sensor
PCB of the indoor unit
* 6Outdoor unit thermistor sensor errorOutdoor unit thermistor sensor
PCB of the outdoor unit
* 9Float switch errorDrain pump, Float switch
Drain system
DIP switch (SW2) of the indoor unit (The No.2 and No.4 switches must be at “ON” position.)
* AA Indoor and Outdoor communication errorCommunication cables of indoor and outdoor units
PCB of indoor and outdoor units
*CWired remote controller communication errorWired remote controller cables, Wired remote controller
Main/Sub PCB of the indoor unit
* DOutdoor pipe thermistor sensor errorOutdoor pipe thermistor sensor
PCB of the outdoor unit

CodePossible Cause
E1Indoor unit room thermistor error
E5Indoor unit pipe thermistor error
E6Outdoor unit thermistor error
E9Float switch open error
EACommunication error between indoor unit and outdoor unit
ECCommunication error between wired remote controller and indoor unit
EDOutdoor unit pipe thermistor error
Reservation LED flickering(1Hz period)Indoor temperature sensor abnormal
Operation LED and reservation LED flickering (1Hz period)Indoor pipe temperature sensor abnormal
Operation LED and filter LED flickering (1 Hz period)Outdoor temperature sensor abnormal
Reservation LED filter LED alternating flickering (1Hz period)Float switch open abnormal
Reservation LED and filter LED flickering (1Hz period)Indoor and outdoor communication abnormal
Operation LED and reservation LED alternating flickering (1Hz period)Wired remote controller communication abnormal
Filter LED flickering (1Hz period)Outdoor pipe temperature sensor abnormal

Is your problem not in this list? Maybe it's a common aircon problem we've already encountered. Read more about it here.

CodePossible CauseSolution
E1Short of indoor temperature sensor
Open of Indoor temperature sensor
Check of departure of indoor temperature sensor
Check of PCB open/short
E5Short of indoor heat exchanger sensor
Open of indoor heat exchanger sensor
Check of indoor exchanger sensor departure
Check of PCB open/short
Replacement of sensor
E6Short of outdoor heat exchanger sensor
Open of outdoor heat exchanger sensor
Check of outdoor exchanger sensor departure
Check of PCB open/short
Replacement of sensor
E7Short of heater temperature sensor
Open of heater temperature sensor
Check of heater wiring diagram
Check of sensor attachment location
ELWhen the electrical heater is overheatedCheck of heater temperature sensor departure
Check of PCB open/shore
Replacement of sensor

Error TypeLED Lamp Display
OperationDefrostTimerAirflowFilter
Power resetFlickeringOFFOFFOFFOFF
Error of temperature sensor in the indoor unit (Open/Short)OFFOFFFlickeringOFFOFF
Error of the outdoor temperature sensor
Error of the condenser temperature sensor
Error of the discharge temperature sensor
FlickeringOFFOFFFlickeringOFF
1. No communication for 2 minutes between indoor units (Communication error for more than 2 minutes)
2. Indoor unit receiving the communication error from outdoor unit
3. Outdoor unit tracking 3 minutes error
4. When sending the communication error from the outdoor unit, the mismatching of the communication numbers and installed numbers after completion of tracking (Communication error for more than 2 minutes)
OFFOFFFlickeringFlickeringOFF
1. Error of electronic expansion valve close
2. Error of electronic expansion valve open
3. 2nd detection of high temperature cond
4. 2nd detection of high temperature discharge
5. Error of reverse phase
6. Compressor down due to 6th detection of freezing
OFFOFFFlickeringFlickeringFlickering
Detection of the float switchOFFOFFOFFFlickeringFlickering
Error of setting option switches for optional accessoriesOFFOFFFlickeringOFFFlickering
EEPROM option errorFlickeringFlickeringFlickeringFlickeringFlickering

CodePossible Cause
101Indoor unit Communication Error
102Indoor/Outdoor unit Communication Time Out Error 60 Packet Over data
201Indoor unit is not connected
203Communication Error between Outdoor Main and Inverter Micom (Occurred after 1 minute detection in Main and Inverter)
121Indoor Temp. Sensor (Open/Short Error)
122Indoor Unit Eva in Sensor (Open/Short Error)
128Indoor Unit Eva in Sensor Separation
221Outdoor Temp Sensor Error (Open/Short Error)
237CONDTemp. Sensor Error (Open/Short Error)
251Inverter Compressor Discharge Temp, sensor Error (Open/Short Error)
425Power cable miss connection error
153Indoor Float Switch 2nd Detection
460Outdoor unit - indoor unit communication wire miss connection (Connected to Power terminal)
554Outdoor unit refrigerant full leakage (Gas leak)
458Outdoor Fan 1 Error
475Outdoor Fan 2 Error
416Discharge over temperature
461(Inverter) Compressor starting error
462Primary Current Over Trip error
464(Inverter) IPM Over Current(O.C)
467(Inverter) Compressor Rotation error
468(Inverter) Current Sensor error
469(Inverter) DC LINK Sensor error
471(Inverter) EEPROM Read/Write Error
474(Inverter) Heatsink temperature over Error
556Outdoor unit Capacity Setup option error
601Communication error between Indoor unit and wired remote control
602Communication error between Master and Slave wired remote control
606COM1/COM2 Cross-installed error
EAError of setting option for wired remote control COM2

CodePossible Cause
601Communication error between wired remote control < -> indoor unit/ventilation system (ERV) (When communication has stopped for 3 minutes after detecting indoor unit/ventilation system (ERV) and wired remote control)
602Communication error between wired remote control < -> indoor unit/ventilation system (ERV) (When communication has stopped for 3 minutes after detecting indoor unit/ventilation system (ERV) and wired remote control)
604Tracking 10 or more errors between wired remote control < -> indoor unit/ventilation system (ERV)
606- COM1, COM2 crossing connection error
- When wired remote control is connected to indoor unit COM 1 (F1,F2) terminal
607- Multiple master error
- Error occurred during installation when two wired remote controls are both set as masters in one communication line (This is not possible to detect if the communication polarity is connected in reversed polarity.)
608Ventilation system (ERV) is not installed incase of outside gearing.
609Indoor unit is not installed in case of outside gearing (when the indoor unit is not detected after outside gearing option setting and tracking are finished).
618- Exceeded maximum no. of installation for indoor unit/ventilation system (ERV) (16 equipment devices)
- A reset is required after checking the number of indoor unit/ventilation system (ERV) installations
619- Mixed installation error for°C/°F indoor unit
- Error occurs when mixed indoor units of °C and "F settings are installed
620-Wired remote control °C/°F setting error
-This error occurs if the indoor unit is set in °C while the wired remote control is set in °F or vice versa.
621This error occurs when the option settings of the master and slave wired remote controls are different from each other.
627Slave wired remote control installation error (when two slave wired remote controls are installed)
630Normal operation option setting error (when normal operation is selected with the wired remote control for a ventilation system (ERV) that does not support the normal operation option)
631Automatic operation option setting error (when automatic operation is selected with the wired remote control for a ventilation system (ERV) that does not support the automatic operation option)
653Temperature sensor open/short error
654- FRAM READ/WRITE error
- Damper error [error is detected when there is no input for 100 seconds (time for about 5 revolutions) during damper output]

LED DisplayExplanation
YellowGreenRed
LED OFFLED OFFLED OFFPower off/VDD NG
LED OFFLED BLINKIPM Over Current(O.C)
LED OFFLED ONLED ONAbnormal Serial communication
LED OFFLED BLINKLED OFFCompressor Starting error
LED OFFLED BLINKLED ONNormal Operation
LED OFFLED ONLED OFFCompressor Lock error
LED OFFLED ONLED BLINKDC-Link voltage under/over error
LED BLINKLED OFFLED BLINKOutdoor temperature sensor error
LED BLINKLED OFFLED ONDischarge over temperature
LED BLINKLED BLINKLED OFFDischarge temperature sensor error
LED BLINKLED BLINKLED ONCurrent sensor error
LED BLINKLED ONLED OFFCompressor limit error
LED BLINKLED ONLED BLINKCoil temperature sensor error
LED BLINKLED ONLED ONImin.Time out Communication
LED ONLED OFFLED OFFFan error
LED ONLED OFFLED BLINKOTP error
LED ONLED OFFLED ONCompressor rotation error
LED ONLED BLINKLED OFFOperation condition secession(Dual only)
LED ONLED BLINKLED BLINKDC-Link voltage sensor error
LED ONLED BLINKLED ONl_Trip error / PFC Over current
LED ONLED ONLED OFFGAS Leak error
LED ONLED ONLED BLINKAC Line Zero Cross Signal out
LED ONLED ONLED ONPower ON reset(l sec)
LED BLINKLED OFFLED OFFCapacity miss match
LED OFFLED BLINKLED BLINKTest Operation at Cooling Mode
LED BLINKLED BLINKLED BLINKTest Operation at Heating Mode

DescriptionLampMain Checking Point
OperationTimerTurbo
Indoor unit room temperature sensor error (open or short)Lamp onLamp blinkLamp on3-2P
Indoor unit heat exchanger temperature sensor error (open or short)Lamp blinkLamp blinkLamp on3-3P
Indoor fan motor malfunctionLamp onLamp onLamp blink3-4P
EEPROM errorLamp blinkLamp blinkLamp blinkOption Setting
Option error (option wasn't set up or option data error)Lamp blinkLamp blinkLamp blinkOption Setting
Outdoor unit errorLamp blinkLamp onLamp blinkRemote Control on/off Outdoor Unit Power Reset