Gree Air Conditioners Error Codes
The fault code is deduced from the number of
times the green LED flashes, blocking unit operation.
C5:Malfunction of
connector jumper: Check if the connector jumper contacts properly. If the PCB
is to be replaced, please take off the old for the new PCB
F1:Malfunction of indoor ambient temperature sensor:Check
if indoor room temperature sensor is connected properly.F2:Malfunction of evaporator temperature sensor:Check if the evaporator temperature is connected properly.
H1:Defrosting:It is normal
H6:Indoor fan block:Check if terminal of the indoor motor is connected properly. Replace the fan motor or the indoor board if disabled.
Refrigerant system high pressure protection E1
Anti-freezing protection E2
Compressor exhaust high temperature protection E4
AC over-current protection E5
Communication failure between indoor unit and outdoor unit E6
Anti-high temperature protection E8
No feedback of indoor fan motor H6
Jumper cap malfunction protection C5
Indoor ambient sensor open or short circuit F1
Indoor tube sensor open or short circuit F2
Outdoor ambient sensor open or short circuit F3
Outdoor tube sensor open or short circuit F4
Exhaust sensor open or short circuit F5
Over load limit / drop frequency F6
Over current limit / drop frequency F8
High exhaust temperature limit / drop frequency F9
Over voltage protection for PN PH
AC current detect circuit malfunction U5
Compressor reverse protection U4
Over compressor phase current protection P5
Inlet tube sensor malfunction b5
Outdoor DC fan motor malfunction L3
Outlet tube sensor malfunction b7
Door malfunction FC
Compressor overload sensor malfunction FE
Defrosting H1
Static clearing dust protection H2
Compressor over load protection H3
System abnormal protection H4
IPM protection H5
PFC protection HC
Compressor loss step protection H7
Heating anti-high temperature drop frequency H0
Startup failure Lc
Compressor protection against loss of phase U2
Compressor phase current detection circuit malfunction U1
Compressor demagnetization protection HE
Loading EEPROM malfunction EE
Communication failure between main board and driver board P6
Capacitor charge malfunction PU
IPM sensor circuit malfunction P7
IPM high temperature protection P8
PN voltage drop protection U3
Low PN voltage protection PL
Current detect circuit malfunction or Current sensor malfunction Pc
Compressor loss of phase protection Ld
Compressor locked rotary protection LE
IPM over temperature limit / drop frequency EU
4-way valve reversal abnormal U7
Disconnection of the exhaust temperature sensor U8
AC power zero voltage detect error U9
Over tube temperature drop frequency FA
Anti-freezing limit / drop frequency FH
E2-F4-F5-F6-F7-F8-F1-F2-F3-F9-FA-FB-F0-E4-E3-E5-E1-E6-FC-FD-EB