Hitachi AC Error Codes and Troubleshooting


Hitachi AC Error Codes and Troubleshooting

Error Codes
Trouble
P01
Pressure ratio protection control
P02
High pressure increase protection
P03
Inverter current protection
P04
Inverter fin temperature increase protection
P05
Discharge gas temperature increase protection at the upper part of the compressor
P06
Low pressure decrease protection
P09
High pressure decrease protection
P0A
Demand current protection control
P0d
Low pressure increase protection
P11
Pressure ratio decrease retry
P12
Low pressure increase retry
P13
High pressure increase retry
Code: 01
Content of Abnormality: Tripping of Protection Device
Leading Cause: Failure of Fan Motor, Drain Discharge, PCB, Relay
Code: 02
Content of Abnormality: Tripping of Protection Device
Leading Cause:  Activation of PSH
Code: 03
Content of Abnormality: Abnormality between Indoor (or outdoor) and Outdoor (or Indoor)
Leading Cause:  Incorrect Wiring. Failure of PCB. Tripping of Fuse. Power Supply OFF.
Code: 04
Content of Abnormality: Abnormality between Inverter and Control PCB
Leading Cause: Failure in Transmission between PCBs
Code: 05
Content of Abnormality: Abnormality of Power Source Wiring
Leading Cause: Reverse Phase Incorrect Wiring
Code: 06
Content of Abnormality: Voltage Drop by Excessively Low or High Voltage to Outdoor Unit
Leading Cause: Voltage Drop of Power Supply, Incorrect Wiring or Insufficient Capacity of Power Supply Wiring
Code: 07
Content of Abnormality: Decrease in Discharge Gas Superheat
Leading Cause:  Excessive Refrigerant Charge, Expansion Valve Open Lock
Code: 08
Content of Abnormality:  Increase in Discharge Gas Temperature
Leading Cause: Insufficient Refrigerant. Ref. Leakage, Clogging or Expansion Valve Close Lock
Code: 09
Content of Abnormality: Tripping of Protection Device
Leading Cause: Failure of Fan Motor
Code: 11
Content of Abnormality:  Inlet Air Thermistor
Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 12
Content of Abnormality: Outlet Air Thermistor
Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 13
Content of Abnormality: Freeze Protection Thermistor
Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 14
Content of Abnormality: Gas Piping Thermistor
Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 19
Content of Abnormality: Failure of Fan Motor
Leading Cause: Failure of Fan Motor
Code: 21
Content of Abnormality: High Pressure Sensor
Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 22
Content of Abnormality: Outdoor Air Thermistor
Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 23
Content of Abnormality: Discharge Gas Thermistor on Comp
Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 24
Content of Abnormality: Evaporating Thermistor


Leading Cause: Failure of Thermistor, Sensor, Connection
Code: 29
Content of Abnormality: Low Pressure Sensor
Leading Cause: Failure of Thermistor, Sensor, Connection

Code: 30
Content of Abnormality: Incorrect Wiring Connection
Leading Cause: Incorrect Wiring Connection between Outdoor Unit, CH Unit and Indoor Unit
Code: 31
Content of Abnormality: Incorrect Setting of Outdoor and Indoor Unit
Leading Cause: Incorrect Setting of Capacity Code
Code: 32
Content of Abnormality: Abnormal Transmission of Other Indoor Unit
Leading Cause: Failure of Power Supply, PCB in Other Indoor Unit. Failure of Other Indoor Unit of the Same Refrigerant Cycle.
Code: 35
Content of Abnormality: Incorrect Setting in Indoor/Outdoor Unit No.
Leading Cause: Existence of the same Indoor Unit No. in the same refrigerant cycle
Code: 38
Content of Abnormality: Abnormality of Protective Circuit in Outdoor Unit
Leading Cause: Failure of Indoor Unit PCB. Incorrect Wiring Connection to PCB in Outdoor Unit
Code: 39
Content of Abnormality: Abnormality of Running Current at Constant Compressor
Leading Cause: Overcurrent, Melted Fuse of Failure of Current Sensor
Code: 43
Content of Abnormality: Pressure Ratio Decrease Protection Activating
Leading Cause: Failure of Compressor, Inverter
Code: 44
Content of Abnormality: Low Pressure Increase Protection Activating
Leading Cause: Overload to Indoor in Cooling, High Temperature of Outdoor Air in Heating Expansion Valve Open Lock
Code: 45
Content of Abnormality: High Pressure Increase Protection Activating