My Blog List

Trane Air Conditioner Error Codes


Trane Air Conditioner Error Codes

  1. Trane Split System Error Codes
  2. Mini TVR 5G Error Codes
  3. Ceiling-Cassette Error Codes
1-Trane Split System Error Codes:
Trane Split AC Error Codes
9, 12 MBH – 60 and 50 Hz ( No LED light on outdoor PCB)
Error Code
Problem
EE
Storage slug
E1
Indoor PCB malfunction
E2
Anti-freezing protection
H4
Overload system
H6
No motor of indoor unit feedback
F2
Indoor pipe temperature sensor malfunction
F1
Internal ambient temperature sensor malfunction
UF
Zero passage abnormal
H3
Overload of compressor
Lc
Startup failure
UH
No motor of outdoor unit feedback
E5
Overcurrent protection
U7
4-way valve conversion abnormal
U1
Phase current detection malfuntion of compressor
2-Trane Mini TVR 5G Error Codes:

Trane Air Conditioner Error Codes
Malfunction Code Of Outdoor Unit (12/14/16kw):
Display: H0
Malfunction or Protection: M_Home unmatching
Display: E0
Malfunction or Protection: EEPROM Fault
Display: E2
Malfunction or Protection: Communication fault of the outdoor chip and the indoor chip
Display: E3
Malfunction or Protection: Communication error between Main board and IR341
Display: E4
Malfunction or Protection: Outdoor unit sensor fault
Display: E5
Malfunction or Protection: Voltage protection fault
Display: E6
Malfunction or Protection: Direct-current fan fault
Display: E7
Malfunction or Protection: Heating fan fault in the area A lasts for 5 minutes
Display: E8
Malfunction or Protection: There are two times E6 fault in 10 minutes (recovery will be after power off)
Display: P0
Malfunction or Protection: The cooling fin high temperature protection
Display: P1
Malfunction or Protection: High pressure protection
Display: P2
Malfunction or Protection: Low pressure protection
Display: P3
Malfunction or Protection: Compressor current protection
Display: P4
Malfunction or Protection: Discharge temperature protection
Display: P5
Malfunction or Protection: Outdoor condenser high temperature protection
Display: P6
Malfunction or Protection: IPM modules protection
Display: P7
Malfunction or Protection: Evaporator high temperature protection
Display: P8
Malfunction or Protection: Typhoon protection
Display Function Instruction:
  1. When stand by, LED displaying the amount of indoor units online which communicate with outdoor units.
  2. When operation, LED displaying frequency value of compressor.
  3. When defrost, LED displaying “dF”.
Malfunction Code Of Outdoor Unit (8/10.5/18kW):
Display: E2
Malfunction or Protection: Communication malfunction between indoor/outdoor units
Display: E4
Malfunction or Protection: T3&T4 temperature sensor malfunction
Display: E5
Malfunction or Protection: Power voltage protection
Display: E6
Malfunction or Protection: Fan Protection
Display: E7
Malfunction or Protection: Compressor discharge temperature sensor malfunction
Display: E9
Malfunction or Protection: EEPROM malfunction
Display: EA
Malfunction or Protection: A fan in the Aregion run for more than 5 minutes in Heat mode
Display: Eb
Malfunction or Protection: 2 times of E6 protection in 10 minutes
Display: H0
Malfunction or Protection: Communication malfunction between IR341/main board
Display: P1
Malfunction or Protection: Hi-pressure protection
Display: P2
Malfunction or Protection: Low-pressure protection
Display: P3
Malfunction or Protection: Input current protection
Display: P4
Malfunction or Protection: Compressor discharge protection temperature
Display: P5
Malfunction or Protection: Condenser high temperature protection
Display: P6
Malfunction or Protection: Inverter module protection
Display: P8
Malfunction or Protection: Typhoon protection
Display: PE
Malfunction or Protection: Indoor evaporator hi-tempprotection
Display: L0
Malfunction or Protection: Module malfunction
Display: L1
Malfunction or Protection: DC generatrix low voltage protection
Display: L2
Malfunction or Protection: DC generatrix high voltage protection
Display: L3
Malfunction or Protection: Reserved
Display: L4
Malfunction or Protection: MCE malfunction/simultaneously/cycle loop
Display: L5
Malfunction or Protection: Zero speed protection
Display: L6
Malfunction or Protection: Reserved
Display: L7
Malfunction or Protection: Wrong phase protection
Display: L8
Malfunction or Protection: Speed difference>15Hz protection between the front and the back clock
Display: L9
Malfunction or Protection: Speed difference>15Hz protection between the real and the setting speed
Display Function Instruction:
  1. When stand by, LED displaying the amount of indoor units online which communicate with outdoor units.
  2. When operation, LED displaying frequency value of compressor.
  3. When defrost, LED displaying “dF”.
3-Ceiling-Cassette Error Codes:
Trane Cassette Indoor Unit Error Codes
Error code: 416
Explanation: Compressor down due to protection control of the discharge temperature sensor
Error code: 450
Explanation: Error due to condenser temperature sensor when in cooling mode
Error code: 451
Explanation: Error of the low pressure switch (Protection control)
Error code: 425
Explanation: Reverse phase error (Protection control)
Error code: 551
Explanation: In removing frost
Error code: 221
Explanation: Error of outdoor temperature sensor (Open/Short)
Error code: 237
Explanation: Error of condenser temperature sensor (Open/Short)
Error code: 201
Explanation: System down caused by communication error after completion of tracking Mismatching of indoor unit quantity setting error after completion of tracking 5 times
Error code: 251
Explanation: Error of discharge temperature sensor (Open/Short)
Error code: 121
Explanation: Error of temperature sensor in the indoor unit (Open/Short)
Error code: 122
Explanation: Error of the heat exchanger sensor in the indoor unit (Open/Short)
Error code: 419
Explanation: Error of electronic expansion valve open in the outdoor unit (when it is detected more than once)
Error code: 422
Explanation: Error of electronic expansion valve close in the outdoor unit (when it is detected more than once)
Error code: 601
Explanation: Error of communication between the indoor unit and the wired remote controller
Error code: 602
Explanation: Master wired remote controller / slave wired remote controller
Error code: 606
Explanation: Polarity error (F1/F2, F3/F4 switched)
Error code: EA
Explanation: Error of setting option for wired remote controller COM2


voltas AC unlock passwords