Error Codes
Trouble
E1
High pressure protection of system
E2
Anti-freezing protection
E3
Block or Low pressure of refrigerant system
E4
Compressor exhaust high temperature protection
E5
AC over-current protection
E6
Communication failure between indoor unit and outdoor unit
E8
Anti-high temperature protection
H4
Anti-high temperature protection
H6
No feedback of indoor fan motor
C5
Jumper cap malfunction protection
LP
Indoor unit and outdoor unit doesn't match
L3
Outdoor DC fan motor malfunction
L9
Power protection
Fo
Gathering refrigerant
F1
Indoor ambient sensor open or short circuit
F2
Indoor tube sensor open or short circuit
F3
Outdoor ambient sensor open or short circuit
F4
Outdoor tube sensor open or short circuit
F5
Exhaust sensor open or short circuit
How to fix E1? High pressure protection of system
Ac Status: During the cooling and drying operation, all loads stop operating except the indoor fan. During the heating operation, the entire unit stops.
Possible Reasons:
  1. Refrigerant is superabundant;
  2. Poor heat exchange (including a bad radiating environment ); the ambient temperature is too high.
How to fix E2? Anti-freezeprotection
Ac Status: During the cooling and drying operation, the compressor and outdoor fan stop while the indoor fan operates.
Possible Reasons:
  1. Poor air-return in indoor unit;
  2. Fan speed is abnormal;
  3. Evaporator is dirty.
How to fix E4? High discharge temperature protection of compressor
Ac Status: During the cooling and drying operation, the compressor and outdoor fan stop while the indoor fan operates. During the heating operation, all loads stop.
Possible Reasons: Refer to the malfunction analysis (discharge protection, overload).
How to fix E5? Overcurrent protection
Ac Status: During the cooling and drying operation, the compressor and outdoor fan stop while the indoor fan operates. During the heating operation, all loads stop.
Possible Reasons:
  1. Supply voltage is unstable;
  2. Supply voltage is too low and the load is too high;
  3. Evaporator is dirty.
How to fix E6? Communication Malfunction
Ac Status: During the cooling operation, the compressor stops while the indoor fan motor operates. During the heating operation, the entire unit stops.