Insignia Portable
Air Conditioner Error Codes
When any of the following
error indicators appear on the LED display, turn off your air conditioner and
call a professional maintenance technician or service center.
Error Codes
|
Trouble
|
FL
|
The water collection tank is full and must be drained.
Drain the tank and reset your settings.
|
E1
|
Coil temperature sensor error
|
E2
|
Indoor temperature sensor error
|
E3
|
Anti-freezing protection. The air conditioner coil
temperature is too low and the unit has turned off automatically. The unit
resets itself when the temperature reaches 46.4°F (8°C).
|
Troubleshooting
Problem: Air
conditioner does not start
Possible cause:
- The air
conditioner is unplugged.
- The
fuse on the circuit is blown or the circuit breaker is tripped.
- Power
failure.
- The
current interrupter device in the power cord has tripped.
- FL
appears on the display.
- Room temperature is less than the set
temperature.
Possible solution:
- Make
sure that the air conditioner is plugged in and that the plug is pushed
completely into the outlet.
- Check
the house fuse/circuit breaker box and replace the fuse or reset the
circuit breaker.
- If a
power failure occurs, the air conditioner turns off. When the power is
restored, wait three minutes to restart the air conditioner to
prevent tripping the compressor overload.
- Press
the RESET button located on the power cord plug. If the RESET button will
not stay engaged, discontinue use of the air conditioner and contact a
qualified service technician.
- The water
collection tank is full and must be drained. Drain the tank and reset your
settings.
- This is normal. The air conditioner
automatically shuts off when the room temperature equals, or is less than,
the set temperature. Adjust the temperature setting, if needed.
Problem: The
air conditioner does not cool
Possible cause:
- Airflow
is restricted.
- The
temperature control may not be set correctly
- The air
filter is dirty.
- There
is a heat source or too many people in the room.
- The
room may have been hot.
- The exhaust hose is not connected or is
blocked.
Possible solution:
- Make
sure that there are no curtains, blinds, or furniture blocking the front
of the air conditioner.
- In COOL
mode, decrease the temperature setting by pressing the ∇
button on the panel or the remote control.
- Clean
the filter at lease every two weeks.
- Move
any heat sources from the room.
- You
need to allow time for the room to cool down after you first turn on the
air conditioner.
- Connect the exhaust hose and make sure that it
is not obstructed and is functioning properly.
Problem: The
air conditioner is freezing up
Possible cause: The
cooling coils are iced over.
Possible solution: Ice
may block the air flow and obstruct the air conditioner from properly cooling
the room. Set the mode control to High Fan or High Cool.
Problem: The
air conditioner runs too often or too long
Possible cause:
- The
area to be cooled is too large for the air conditioner.
- Doors or windows are open.
Possible solution:
- Consult
your Insignia technician for the air conditioner capacity required to cool
the desired area.
- Make sure that doors and windows are closed.
Problem: The
venting hose is hot
Possible cause: When
the air conditioner runs continuously for a long time, the hose becomes hot.
Possible solution: This
is normal.
Problem: The
air conditioner is too loud
Possible cause:
- The
unit may seem rather loud for the first two or three minutes of operation.
- A soft, swishing noise can be heard
immediately after turning the unit on or off, and during operation.
Possible solution:
- This is
the sound of the compressor starting up and is normal.
- This is the sound of the liquid refrigerant
flowing in the unit and is normal.
Problem: The
air conditioner makes an odd noise
Possible cause: An
audible gurgling noise may be heard when the unit is operated on a gently
sloping floor.
Possible solution: Place the unit on a level floor.