Fujitsu Ac Error Codes & Troubleshooting Method
This model is non-insulated PCB that doesn’t take the insulated structure on the PCB from this fiscal year. Be careful that it is likely to get a hock when it touches the charge part when checking. Moreover, there is a possibility of getting a shock even if it touches the secondary circuit of the display PCB or the stepping motor, etc.
If You Not Solve This Problem Then Call A Experienced Technician.
Fujitsu AC Wired Remote Controller Error Codes
When EE:EE is displayed on remote control , press “Energy Save” & “Zone Control” buttons simultaneously for longer than 3 secs. The error code will then be displayed on the LCD.
Error Codes
Cause
E0:00
Coms error - indoor to remote
E1:00
Coms error - indoor to outdoor
E2:00
Return air thermistor open circuit
E3:00
Return air thermistor short circuit
E4:00
Indoor coil thermistor open
E5:00
Indoor coil thermistor shorted
E6:00
Outdoor coil thermistor open
E7:00
Outdoor coil thermistor shorted
EA:00
Outdoor ambient thermistor open
Eb:00
Outdoor ambient thermistor shorted
Ec:00
Discharge pipe themistor open
Ed:00
Discharge pipe thermistor shorted
EE:00
High Pressure problem
EF:00
Discharge pipe temp. Problem - too high = short of gas
OO
ID to RC Comms Fail
O1
ID to OD Comms Fail
O2
ID Air Sensor Open
O3
ID Air Sensor Close
O4
ID Pipe Sensor Open
O5
ID Pipe Sensor Close
O6
OD Pipe Sensor Fail
O8
Power Source Connection Failure
O9
Drain Problem Float switch operated
OA
OD Air Sensor Fail
OC
Discharge sensor Fail
OE
Outdoor High Pressure Heatsink error
11
OD PCB Fail
12
ID Fan Fail
13
OD Signal Abnormal ID signal error

In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the Power Supply Plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to disconnect the Power Supply Plug or turn off your circuit breaker to ensure that power is completely off.
Before requesting service, perform the following checks:
Symptom: Doesn’t operate immediately
Problem:
  • If the unit is stopped and then immediately started again, the compressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
  • Whenever the Power Supply Plug is disconnected and then re- connected to a power outlet, the protection circuit will operate for about 3 minutes, preventing unit operation during that period.

Symptom:

 Noise is heard
Problem:
  • During operation and immediately after stopping the unit, the sound of water flowing in the air conditioner’s piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
  • During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the front cover due to temperature changes.
  • During Heating operation, a sizzling sound may be heard occasional. This sound is produced by the Automatic Defrosting operation.
Symptom: Smells
Problem: Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.
Symptom: Mist or steam are emitted
Problem:
  • During Cooling or Dry operation, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting.
  • During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the unit. This is due to Automatic Defrosting operation.

Symptom: 

Airflow is weak or stops
Problem:
  • When Heating operation is started, fan speed is temporarily very low, to allow internal parts to warm up.
  • During Heating operation, if the room temperature rises above the thermostat setting, the outdoor unit will stop, and the indoor unit will operate at very low fan speed. If you wish to warm the room further, set the thermostat for a higher setting.
  • During Heating operation, the unit will temporarily stop opera- tion (between 7 and 15 minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, the OPERATION Indicator Lamp will flash.
  • The fan may operate at very low speed during Dry operation or when the unit is monitoring the room’s temperature.
  • During SUPER QUIET operation, the fan will operate at very low speed
  • In the monitor AUTO operation, the fan will operate at very low speed.

Symptom:

 Water is produced from the outdoor unit
Problem: During Heating operation, water may be produced from the outdoor unit due to Automatic Defrosting operation.
Symptom: The AIR CLEAN Indicator Lamp (green) will begin to slowly flash (as shown in the figure):
Problem: After approximately 400 hours of Air Cleaning Mode use, the AIR CLEAN Indicator Lamp will begin to flash slowly (as shown in the figure). When this occurs, please stop the system, remove the mains socket and carry out maintenance on the dust collecting unit’s air filter.
Symptom: The AIR CLEAN Indicator Lamp (green) will begin to flash quickly (as shown in the figure):
Problem: After approximately 500 hours of Air Cleaning Mode use, the AIR CLEAN Indicator Lamp will begin to flash quickly (as shown in the figure). At this point, Air Cleaning will stop functioning. Please stop the system, remove the mains socket and carry out maintenance on the dust collecting unit’s air filter.