Friedrich AC Error
Codes and Troubleshooting
- Portable
Error Codes
- PTAC
Error Codes
- Heat
Pump Error Codes
- Multi
Zone Air Conditioner
- Room/Window Air Conditioner
1.Friedrich
Portable Error Codes:
Error Code
|
Problem
|
EA
|
If the display reads "EA" , the room temperature
sensor has failed. Contact your Authorized
|
ES
|
If the display reads "ES" , the evaporator
temperature sensor has failed. Contact your Authorized
|
E4
|
If the display reads "E4" , the display panel
communication has failed. Contact your Authorized
|
P1
|
If the display reads "P1" , bottom tray is full.
Carefully move the unit to a drain location, remove the bottom drain plug and
let the water drain away. Restart the machine until the "P1" symbol
disappears. If error repeats, call for service.
|
Air conditioner will not operate.
|
Wall plug disconnected. Push plug firmly into wall outlet.
|
Plug Current Device Tripped. Press the RESET button.
|
|
House fuse blown or circuit breaker tripped. Replace fuse
with time delay type or reset circuit breaker.
|
|
Control is OFF. Turn
|
|
Air from unit does not feel cold enough.
|
Room temperature below 60°F (16°C). Cooling may not occur
until room temperature rises above
|
60°F (16°C).
|
|
Temperature sensing element touching cold coil, located
behind air filter. Straighten away from coil.
|
|
Reset to a lower temperature.
|
|
Compressor shut-off by changing modes. Wait approximately
3 minutes and listen for compressor to
|
|
restart when set in the COOL mode.
|
|
Noise when unit is cooling.
|
Air movement sound. This is normal. If too loud, set to
lower FAN setting.
|
Window vibration - poor installation. Refer to
installation instructions or check with installer.
|
|
Water dripping INSIDE when
|
Improper installation. Tilt air conditioner slightly to
the outside to allow water drainage. Refer to
|
unit is cooling.
|
installation instructions or check with installer.
|
Water dripping OUTSIDE when
|
Unit removing large quantity of moisture from humid room.
This is normal during excessively humid days.
|
unit is cooling.
|
|
Remote Sensing Deactivating
|
Remote control not located within range. Place remote
control within 20 feet & 120° radius of the
|
Prematurely
|
front of the unit.
|
Room too cold.
|
Set temperature too low. lncrease set temperature.
|
Friedrich
Portable AC Troubleshooting
Problem: The
airconditioner doesn’t work
Possible Cause:
- There
is a power failure
- The
plug is not connected
- The
timer is unable to work
- The main switch has not been pressed
Remedies:
- Wait
for the power return
- Connect
the plug
- Provide
repairment
- Press the main switch
Problem: The
airconditioner works for short period only
Possible Cause:
- The set
temperature is too close to the room’s temperature
- There
is something blocking the suction vent on the back of condenser
- The fan on the condenser is blocked
Remedies:
- Decrease
the setting temperature
- Remove
any obstacles
- Provide repairment
Friedrich Portable AC Remote Control
Problem: The
airconditioner switches are off constantly
Possible
Cause: Malfunction
Remedies: Turn off
the appliance remove the plug and contact the service center
Problem: The
airconditioner works but it does not cool the room
Possible Cause:
- There
is a window opened
- There
is a source of heat operating in the room (burner, lamp, etc.), orthe room
is crowded
- The air
filter is clogged
- The
capacity of the air conditioner is not suitable for the conditions or size
ofthe room
- The evaporator is frozen
Remedies:
- Close
the window
- Remove/switch
off the source of heat
- Decrease
the set temperature
- Clean
the filter
- Clean
the airfilter
- Change
the purifier filter, if necessary
- Do not make the appliance operating at too low
temperature(below22°C)