Delonghi Portable AC Error Codes
Error Codes
|
Problem
|
LE
|
Low Temperature (frost prevention). The appliance is
fitted with a frost protection device to avoid excessive formation of ice.
The appliance starts up again automatically when the defrosting process is
completed.
|
HL
|
High Level (internal tray full). Empty the internal safety
tray following the instructions in the section “End of season operations”. If
it reoccurs in cooling mode, contact your local authorised customer services.
In heating mode: empty the internal tray.
|
CF
|
Change filter. When this message is displayed, the water
filter needs replacing as described in the section: “Replacing the limescale
filter”.
|
PF
|
Probe Failure (sensor damaged). If this is displayed,
contact your local authorised service centre.
|
F1
|
Failure 1. This message could appear if the water filter
is particularly clogged. See section: “Replacing the limescale filter”. If
the filter has been replaced recently, contact your local authorised service
centre.
|
Lo
|
Low Temperature - Room temperature is too low.
|
H1
|
High Temperature - Room temperature is too high.
|
E1
|
Probe Failure ( Sensor Damaged).
|
The appliance has a
self diagnosis system to identify a number of malfunctions.
Error messages are displayed on the appliance display.
After that you can
easily download our mobile application and search all delonghi ac error codes
and also search other world wide
brands error codes complete lists.
Delonghi Portable Air Conditioner Error Codes – LE HL
CF PF F1
Troubleshooting
Problem: The air conditioner does not come on
Cause:
- there
is no current
- Check
the power maybe main switch not turned on
- the internal safety device has tripped
Solution:
- wait
- plug
into the mains
- call the Service Centre
Problem: The air conditioner works for a short time only
Cause:
- there
are bends or kinks in the air exhaust hose
- something is preventing the air from being
discharged
Solution:
- position
the air hose correctly, keeping it as short and free of curves as possible
to avoid bottlenecks.
- check and remove any obstacles obstructing air
discharge
Problem: The air conditioner works, but does not cool the
room
Cause:
- windows,
doors and/or curtains open
- there
are heat sources in the room (oven, hairdryer, etc)
- the air
exhaust hose is detached from the appliance
- dust filters clogged
Solution:
- close
doors, windows and curtains, bearing in mind the “tips for correct use”
given above
- eliminate
the heat sources
- fit the
air exhaust hose in the housing at the back of the appliance
- clean or replace the filters as described
above
Problem: During operation, there is an unpleasant smell in
the room
Cause: dust filter and
(when present) electrostatic filter clogged
Solution: clean the
filters as described above
Problem: The air conditioner does not operate for about
three minutes after restarting it
Cause: the internal
compressor safety device prevents the appliance from being restarted until
three minutes have elapsed since it was last turned off.
Solution: wait. This
delay is part of normal operation.
Problem: The symbol and one of the following messages LT /
HL/Cf/PF / FI appears on the appliance display:
Cause: The appliance
has a self diagnosis system to identify a number of malfunctions.