Chunlan Air
Conditioner Error Codes
Error Codes
|
Problem
|
E0
|
High-pressure protection
|
E1
|
Antifreeze protection
|
E2
|
ID ambient temp probe short circuit
|
E3
|
ID pipe temp probe short circuit
|
E4
|
OD pipe temp probe short circuit
|
E5
|
Communication failure
|
E6
|
Phase sequence protection
|
E7
|
Overcurrent protection
|
E8
|
Load relief protection
|
E9
|
Low-pressure protection
|
Chunlan
Air Conditioner Error Codes / E0-E1-E2-E3-E4-E5-E6-E7-E8-E9
Common TroubleshootingIn case of AC failure, immediately cut off power supply. Check the following before requesting maintenance:
Failure: Machine not operating
Causes:
- Power off
- Power not meeting requirement
- Molten fuse or open CB
- Use when power is resumed
- Check power supply before use
- Replace fuse or close circuit breaker
Causes:
- Clogged air strainer
- ID or OD unit air intake clogged
- Improper temp control setting
- Open door/window
- Clean air strainer
- Remove obstacles
- Reset temperature control
- Close doors/windows
This product features high efficiency, energy saving, mild and silent operation, computerized intelligent control and healthy fresh air etc.
In addition, wire and wireless controls are provided for easy operation.
The product can be widely used in large area, multi-room composite compartment/houses, villa, and medium and small restaurants, bars, leisure and recreation sites.
Chunlan
Air Conditioner Ordinary wire controller
Note:1. For relevant models and parameters provided in this manual, actual products and nameplate information shall govern;
2. This manual has been carefully checked. In case of printing error, our company shall not bear responsibility for the consequences.
3. Our company is in constant
technology advancement and product series and sizes will be adjusted from
time to time. Please note information of our new products.