Aux AC Error Codes
Error Codes
|
Problem
|
E4
|
PG motor feedback is abnormal. The display precedence
level: 1
|
E1
|
Plastic temp sensor is abnormal. The display precedence
level: 2
|
E3
|
Copper temp sensor is abnormal (indoor). The display
precedence level: 3
|
E2
|
Copper temp sensor is abnormal (outdoor). The display
precedence level: 4
|
AUX Ac Error Codes
2. H (Except KFR-25G/H) H1 HA HB series faults display:
- Fault
source: PG motor feedback is abnormal
- Display
mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault
source: Copper temp sensor is abnormal (indoor)
- Display
mode: Timing light twinkles 2 times in every 8 seconds
- The display precedence level: 3
- Fault
source: Copper temp sensor is abnormal (indoor)
- Display
mode: Timing light twinkles 1 times in every 1 seconds
- The display precedence level: 4
3. H(Y) Model Aux Ac Error Codes:
- Fault
source: PG motor feedback is abnormal
- Display
mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault
source: Copper temp sensor is abnormal (indoor)
- Display
mode: Timing light twinkles 2 times in every 8 seconds
- The display precedence level: 3
- Fault
source: Copper temp sensor is abnormal (outdoor)
- Display
mode: Timing light twinkles 1 times in every 1 seconds
- The display precedence level: 4
4. EA EC EM EY EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display
series ac faults:
- Fault
source: PG motor feedback is abnormal
- Display
mode: E4
- The display precedence level: 1
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: E1
- The display precedence level: 2
- Fault
source: Copper temp sensor is abnormal (indoor)
- Display
mode: E3
- The display precedence level: 3
5. All of the
other E series except EA EC EM EY EZ EAA EAD:
- Fault
source: PG motor feedback is abnormal
- Display
mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault
source: Copper temp sensor is abnormal (indoor)
- Display
mode: Timing light twinkles 2 times in every 8 seconds
- The display precedence level: 3
6. QA QB QD
digital display series ac faults:
- Fault
source: PG motor feedback is abnormal
- Display
mode: E4
- The display precedence level: 1
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: E1
- The display precedence level: 2
- Fault
source: Copper temp sensor is abnormal
- Display
mode: E3
- The display precedence level: 3
- Fault
source: Over-current oprotection
- Display
mode: E6
- The display precedence level: 4
7. QC QQ light
display Aux Ac Error Codes:
- Fault
source: PG motor feedback is abnormal
- Display
mode: Timing light twinkles 4 times in every 8 seconds
- The display precedence level: 1
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: Timing light twinkles 1 times in every 8 seconds
- The display precedence level: 2
- Fault
source: Copper temp sensor is abnormal
- Display
mode: Timing light twinkles 3 times in every 8 seconds
- The display precedence level: 3
- Fault
source: Over-current oprotection
- Display
mode: Timing light twinkles 6 times in every 8 seconds
- The display precedence level: 4
8. Faults display of 18000BTU~24000BTU wall unit series
ac non-digital tube displays:
- Fault
source: PG motor feedback is abnormal
- Display
mode: Timing light twinkles 1 times in every 8 seconds
- The
display precedence level: 2
- appearance: System turns off
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: Timing light twinkles 2 times in every 8 seconds
- The
display precedence level: 3
- appearance: System turns off
- Fault
source: Copper temp sensor is abnormal
- Display
mode: Timing light twinkles 8 times in every 8 seconds
- The
display precedence level: 4
- appearance: System doesn’t turns off
Digital tube displays:
- Fault
source: PG motor feedback is abnormal
- Display
mode: E1
- The
display precedence level: 2
- appearance: System turns off
- Fault
source: Plastic temp sensor is abnormal
- Display
mode: E3
- The display
precedence level: 3
- appearance: System turns off
- Fault
source: Copper temp sensor is abnormal
- Display
mode: E2
- The
display precedence level: 4
- appearance: System doesn’t turn off
- E1:
Temperature sensor of air intake fault
- E2:
Temperature sensor of outdoor coil fault
- E3:
Temperature sensor of indoor coil fault
- E4: PG motor of indoor unit feedback fault
AUX AC Wall Mounted Error Codes
Self-check
information: Hint to
defrosting
- Self-check
code of luminotron: Flicker 1 time/1s
- Digital self-check code: Indicates “dF“or
defrosting indicator displays
Self-check
information: Hint to defense
against cold wind
- Self-check
code of luminotron: Flicker 1 time/3s
- Digital self-check code: Fan motor
picture not running
Self-check
information: Failure of room
temperature sensor
- Self-check
code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)
- Digital self-check code: E2/(L2)
Self-check
information: Failure of coiled
pipe sensor
- Self-check
code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)
- Digital self-check code: E3/(L1)
Self-check
information: Abnormality of
outdoor unit
- Self-check
code of luminotron: Flicker 4 times/6s (luminating)
- Digital self-check code: E4/(E5)
Self-check
information: Without feedback
of internal fan motor
- Self-check
code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)
- Digital self-check code: E5/(L6)
Self-check
information: Zero crossing
signal without current
- Self-check
code of luminotron: Flicker 6 times/8s
- Digital self-check code: E6
Self-check
information: External feedback
failure
- Self-check
code of luminotron: Flicker 7 times/9s
- Digital self-check code: E7
Self-check
information: Overheat
protection
- Self-check
code of luminotron: Flicker 8 times/10s
- Digital self-check code: E8
Self-check
information: Water pump
failure
- Self-check
code of luminotron: Flicker 9 times/11s
- Digital self-check code: E9
Troubleshooting
Guide
Problem: The motor is heard operating but the
air-conditioner dose not work when the indoor unit is powered on
Cause: Since the
air-conditioner is powered on.
it will come to working
condition as long as you press the ON/OFF button of the remote control and the
signal is well received.
Problem: The compressor stops running but the indoor fan
motor keeps working when it is at cooling mode with the indoor temperature
higher than set temperature.
Cause: If you turn
off the air-conditioner and restart it immediately.
it will return to
normal in 3 minutes, after that, the air-conditioner will automatically adjust
the indoor fan speed to what you set.
Problem: The compressor works discontinuously at
dehumidifying mode.
Cause: The
air-conditioner will automatically control the working of the compressor
according to the inside temperature
Problem: The air-conditioner dose not work while the LED
display is on.
Cause: The TIMER
is set with the air-conditioner,it will be in hold on condition.
If the TIMER setting is
cancelled, the air-conditioner will return to normal working condition.
Problem: The compressor works discontinuously at cooling
and the indoor fan motor slows down.
Cause: The
compressor stops internally or the fan motor slows down
to prevent the indoor
heat exchanger from being frozen.