Error signals on the
display:
In case of error, the
display on the indoor unit shown the following error codes:
Error Code
|
Description of the trouble
|
E0
|
Indoor unit EEPROM parameter error.
|
E1
|
Indoor/outdoor units communication error.
|
E2
|
Zero-crossing signal detection error.
|
E3
|
Indoor fan speed has been out of control.
|
E4
|
Open circuit or short circuit of indoor room temperature
T1 sensor.
|
E5
|
Open circuit or short circuit of evaporator coil
temperature T2 sensor
|
EC
|
Refrigerant Leakage Detection
|
F1
|
Open circuit or short circuit of an outdoor ambient T4
temperature sensor
|
F2
|
Open circuit or short circuit of condenser coil
temperature T3 sensor
|
F3
|
Open circuit or short circuit of compressor discharge T5
temperature sensor
|
Westinghouse
Air Conditioner Trouble shootings
Malfunction: The appliance does not operate
Possible causes:
- Power
failure/plug pulled out
- Damaged
indoor/outdoor unit fan motor
- Faulty
compressor thermomagnetic circuit breaker
- Faulty
protective device or fuses.
- Loose
connections or plug pulled out
- It
sometimes stops operating to protect the appliance.
- Voltage
higher or lower than the voltage range
- Active
TIMER-ON function
- Damaged electronic control board
- Westinghouse Air Conditioner Remote Control Display
Malfunction: Strange odour
Possible causes: Dirty
air filter
Malfunction: Noise of running water
Possible causes: Back
flow of liquid in the refrigerant circulation
Malfunction: A fine mist comes from the air outlet
Possible causes: This
occurs when the air in the room becomes very cold, for example in the COOLING
or DEHUMIDIFYING/DRY modes.
Malfunction: A strange noise can be heard
Possible causes: This
noise is made by the expansion or contraction of the front panel due to
variations in temperature and does not indicate a problem.
Westinghouse
Air Conditioner Indoor unit display
Malfunction: Insufficient airflow
Possible causes:
- Unsuitable
temperature setting.
- Obstructed
air conditioner intakes and outlets.
- Dirty
air filter.
- Fan
speed set at minimum.
- Other
sources of heat in the room.
- No refrigerant.
Malfunction: The appliance does not respond to commands
Possible causes:
- Remote
control is not near enough to indoor unit.
- The
batteries of remote control nearly has no power.
- Obstacles between remote control and signal
receiver in indoor unit.
Malfunction: The display is off
Possible causes:
- Active
LIGHT function
- Power failure
Malfunction: The display is off
Possible causes:
- Active
LIGHT function
- Power failure
Malfunction: Switch off the air conditioner immediately and cut
off the power supply in the event of:
Possible causes:
- Strange
noises during operation.
- Faulty
electronic control board
- Faulty
fuses or switches.
- Spraying
water or objects inside the appliance.
- Overheated
cables or plugs.
- Very strong smells coming from the appliance.