My Blog List

Sanyo Air Conditioner Error Codes


Sanyo Air Conditioner Error Codes

Error Code
Meaning
S01
Room temperature sensor failure
S02
Indoor heat exchanger sensor failure
S03
Humidity sensor failure
S04
Compressor temperature sensor failure
S05
Outdoor heat exchanger sensor failure
S06
Outdoor air temperature sensor failure
S07
Outdoor electrical current detection faillure
E01
lndoor/outdoor communications failure
E02
HIC circuit failure



Power Tr (transistor) circuit failure
E03
Outdoor unit external ROM (OTP data) failure
E04
Peak current cut Off
E05
PAM circuit failure



Active circuit failure
E06
Compressor discharge overheat prevention activated
E07
Indoor fan operating failure
E08
4-way valve switching failure



Indoor zero-cross failure
E09
No-reirigerant protection
E10
DC compressor drive circuit failure
E11
Outdoor fan operating failure
E12
Outdoor system communications failure



OLR operation



Outdoor power supply open phase



Outdoor coil freezing
E13
Freeze-prevention operation activated

Sanyo Air Conditioner Troubleshooting

If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or service center.
1-Trouble
Air conditioner does not run at all.
Possible Cause
1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. ON/OFF operation button is OFF.
5. Batteries in remote control unit have run down.
Remedy
1. Restore power.
2. Contact service center.
3. Consult with electrician or dealer.
4. Press the button again.
5. Replace batteries.
2-Trouble
Compressor runs but soon stops
Possible Cause
1. Obstruction in front of condenser coil.
Remedy
1. Remove obstruction.
3-Trouble
Poor cooling performance.
Possible Cause
1. Dirty or clogged air filter.
2. Heat source (cooker, heater, or electrical appliance) or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.


5. Thermostat is set too high.
Remedy
1. Clean the air filter to improve the air flow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat out.
4. Remove it to ensure good air flow.
5. Set the temperature lower.
4-Trouble
OPERATION lamp blinks and air conditioner does not operate.
Possible Cause
Trouble in system.
Remedy
Contact service center.

5-Trouble
Clicking sound is heard from the air conditioner.
Possible Cause
In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur.
Remedy
This is normal, and the sound will soon disappear.
6-Trouble
OPERATION lamp lights but outdoor unit will not run.
Possible Cause
The use of cellular phones near the air conditioner may cause disturbance to its normal operation.


voltas AC unlock passwords