Sanyo Air
Conditioner Error Codes
Error Code
|
Meaning
|
S01
|
Room temperature sensor failure
|
S02
|
Indoor heat exchanger sensor failure
|
S03
|
Humidity sensor failure
|
S04
|
Compressor temperature sensor failure
|
S05
|
Outdoor heat exchanger sensor failure
|
S06
|
Outdoor air temperature sensor failure
|
S07
|
Outdoor electrical current detection faillure
|
E01
|
lndoor/outdoor communications failure
|
E02
|
HIC circuit failure
|
Power Tr (transistor) circuit failure
|
|
E03
|
Outdoor unit external ROM (OTP data) failure
|
E04
|
Peak current cut Off
|
E05
|
PAM circuit failure
|
Active circuit failure
|
|
E06
|
Compressor discharge overheat prevention activated
|
E07
|
Indoor fan operating failure
|
E08
|
4-way valve switching failure
|
Indoor zero-cross failure
|
|
E09
|
No-reirigerant protection
|
E10
|
DC compressor drive circuit failure
|
E11
|
Outdoor fan operating failure
|
E12
|
Outdoor system communications failure
|
OLR operation
|
|
Outdoor power supply open phase
|
|
Outdoor coil freezing
|
|
E13
|
Freeze-prevention operation activated
|
Sanyo Air Conditioner Troubleshooting
If your air conditioner
does not work properly, first check the following points before requesting
service. If it still does not work properly, contact your dealer or service
center.
1-Trouble
Air conditioner does
not run at all.
Possible Cause
1. Power failure.
2. Leakage breaker
tripped.
3. Line voltage is too
low.
4. ON/OFF operation
button is OFF.
5. Batteries in remote
control unit have run down.
Remedy
1. Restore power.
2. Contact service
center.
3. Consult with
electrician or dealer.
4. Press the button
again.
5. Replace batteries.
2-Trouble
Compressor runs
but soon stops
Possible Cause
1. Obstruction in front
of condenser coil.
Remedy
1. Remove obstruction.
3-Trouble
Poor
cooling performance.
Possible Cause
1. Dirty or clogged air
filter.
2. Heat source (cooker,
heater, or electrical appliance) or many people in room.
3. Doors and/or windows
are open.
4. Obstacle near air
intake or air discharge port.
5. Thermostat is set
too high.
Remedy
1. Clean the air filter
to improve the air flow.
2. Eliminate heat
source if possible.
3. Shut them to keep
the heat out.
4. Remove it to ensure
good air flow.
5. Set the temperature
lower.
4-Trouble
OPERATION lamp blinks
and air conditioner does not operate.
Possible Cause
Trouble in system.
Remedy
Contact service center.
5-Trouble
Clicking sound is heard
from the air conditioner.
Possible Cause
In heating or cooling
operation, any plastic parts may expand or shrink due to a sudden temperature
change. In this event, a clicking sound may occur.
Remedy
This is normal, and the
sound will soon disappear.
6-Trouble
OPERATION lamp lights
but outdoor unit will not run.
Possible Cause
The use of cellular
phones near the air conditioner may cause disturbance to its normal operation.