Error Code
Description of the trouble
E1
The fault of indoor temperature sensor. RUN lamp: flashes once.
E2
The fault of indoor pipe temperature sensor. RUN lamp: flashes twice.
E3
Malfunction of indoor fan motor. RUN lamp: flashes 6 times.

Troubleshooting

Malfunction: The appliance does not operate
Possible Causes:
  • Power failure/plug pulled out
  • Damaged indoor/outdoor unit fan motor
  • Faulty compressor thermomagnetic circuit breaker
  • Faulty protective device or fuses.
  • Loose connections or plug pulled out
  • It sometimes stops operating to protect the appliance.
  • Voltage higher or lower than the voltage range
  • Active TIMER-ON function
  • Damaged electronic control board
Malfunction: Insufficient airflow, either hot or cold
Possible Causes:
  • Unsuitable temperature setting.
  • Obstructed air conditioner intakes and outlets.
  • Dirty air filter.
  • Fan speed set at minimum.
  • Other sources of heat in the room.
  • No refrigerant.
Malfunction: The appliance does not respond to commands
Possible Causes:
  • Remote control is not near enough to indoor unit.
  • The batteries of remote control nearly has no power.
  • Obstacles between remote control and signal receiver in indoor unit.
Malfunction: The display is off
Possible Causes:
  • Active LIGHT function
  • Power failure
Malfunction: Switch off the air conditioner immediately and cut off the power supply in the event of
Possible Causes:
  • Strange noises during operation.
  • Faulty electronic control board
  • Faulty fuses or switches.
  • Spraying water or objects inside the appliance.
  • Overheated cables or plugs.
  • Very strong smells coming from the appliance.
Ramsond AC Error Codes and Troubleshooting
Malfunction: Strange odour
Possible Causes: Dirty air filter
Malfunction: Noise of running water
Possible Causes: Back flow of liquid in the refrigerant circulation
Malfunction: A fine mist comes from the air outlet
Possible Causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes.
Malfunction: A strange noise can be heard
Possible Causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.