McQuay Air Conditioner Error Codes


McQuay Air Conditioner Error Codes

Error Codes
Trouble
E1
Compressor 2 low pressure faulty
E2
Compressor 2 high pressure faulty
E3
Compressor 2 overload
E4
Indoor coil 2 temperature sensor fault
E5
System 2 leaving water temperature 2 faulty
F2
Indoor coil 1 temperature sensor fault
F4
Return air temperature sensor fault
F6
Communication faulty
F9
Compressor 1 refrigerant leak
FE
Compressor 2 refrigerant leak
H1
Compressor 1 high pressure faulty
H4
Compressor 1 low pressure faulty
L1
Temperature of water entering too high or low
L3
Water flow switch faulty
L4
System 1 leaving water temperature 1 faulty
Wall Mounted K-Series Inverter-Y model

McQuay AC Error Code Diagnosis
00: Normal
UA: Indoor-outdoor Unit Combination Fault

UO: Refrigerant Shortage
U2: Drop Voltage Or Main Circuit Overvoltage
U4: Failure Of Transmission (Between Indoor Unit And Outdoor Unit)
A1: Indoor Pcb Defectiveness
A5: High Pressure Control Or Freeze-up Protector
A6: Fan Motor Fault
C4: Faulty Heat Exchanger Temperature Sensor
C9: Faulty Suction Air Temperature Sensor
EA: Cooling-heating Switching Error
E1: Circuit Board Fault
E5: Ol Started
E6: Faulty Compressor Start Up
E7: Dc Fan Motor Fault
E8: Overcurrent Input
F3: High Temperature Discharge Ppe Control
F6: High Pressrue Control (In Cooling)
H0: Sensor Fault
H6: Operation Fault Due To Faulty Position Detection Sensor
H8: Dc Current Sensor Fault
H9: Faulty Suction Air Temperature Sensor
J3: Faulty Discharge Pipe Temperature Sensor
J6: Faulty Heat Exchanger Temperature Sensor
L3: Electrical Parts Heat Fault
L4: High Temperature At Inverter Circuit Heatsink
L5: Output Overcurrent
P4: Faulty Inverter Circuit Heatsink Temperature Sensor
Error Diagnosis by Wired Controller (MC301):

McQuay Air Conditioner Remote Control Error Codes
E0: System malfunction
E1: Sensor Broken (TH1 discharge Temp.)
E2: Sensor Broken (TH2 inlet coil 1#)
E3: Sensor Broken (TH3 mid coil 1#)
E4: Sensor Broken (TH4 inlet coil 2#)
E5: Sensor Broken (TH5 mid coil 2#)
E6: Sensor Broken (TH6 inlet coil 3#)
E7: Sensor Broken (TH7 mid coil 3#)
E8: Sensor Broken (TH8 ambient temp)
E9: Sensor Broken (TH9 outlet coil)
EA: Sensor Broken (TH10 subcool outlet)
EB: Sensor Broken (TH11 subcool suction)
EC: Sensor Broken (TH12 suction)
EF: Emergency Run
F0: Outdoor Storage Malfunction
F1: Sensor Broken (indoor inlet coil)
F2: Sensor Broken (indoor mid coil)
F3: Sensor Broken (indoor outlet coil)
F4: Sensor Broken (indoor return air)
F5: Sensor Broken (indoor supply air)
F6: Indoor and controller communication malfunction
F7: Ambient temp exceed the limit
F8: 4WV malfunction
F9: Refrigerant leakage
FA: Controller storage malfunction
FB: Water Pump (indoor water pump)
FC: Indoor and outdoor communication malfunction
FE: Outdoor master and slave communication malfunction
H0: Digital comp overload
H1: Fixed Comp1 overload
H2: Fixed Comp2 overload
H3: Fixed Comp3 overload
H4: High pressure too high
H5: Sensor broken, high pressure
H6: Discharge temp too high
L0: Super heat too low
L1: Low pressure too low
L2: Sensor broken, low pressure
10: System malfunction
11: Sensor broken (slave TH1 discharge temp)
12: Sensor broken (slave TH2 inlet coil 1#)
13: Sensor Broken (slave TH3 mid coil 1#)
14: Sensor broken (slave TH4 inlet coil 2#)
15: Sensor broken (slave TH5 mid coil 2#)
16: Sensor broken (slave TH6 inlet coil 3#)
17: Sensor broken (slave TH7 mid coil 3#)
18: Sensor broken (slave TH8 ambient temp)
19: Sensor broken (slave TH9 outlet coil)
1A: Sensor broken (slave TH10 subcool outlet)
1B: Sensor broken (slave TH11 subcool suction)
1C: Sensor Broken (slave TH12 suction)
1F: Emergency run (slave)
20: Outdoor storage (slave)
27: Ambient temp exceed the limit (slave)