Lloyd Air
Conditioner Error Codes
If the system does not
properly operate except the above mentioned cases or the above mentioned
malfunctions is evident, investigate the system according to the following
procedures.
Lloyd
Air Conditioner Error Codes
Troubles and
Causes of Remote Controller;
Before asking for
serving or repairing, check the following points.
Error Code
|
Malfunction
|
E2
|
Room temperature sensor checking channel is abnormal. LED
2 Timer: Flashing
|
E3
|
Pipe temperature sensor checking channel is abnormal. LED
1 Operation: Flashing
|
E4
|
Outdoor pipe TEMP. sensor checking is abnormal. LED 3
Def.Fan: Flashing
|
E6
|
Outdoor malfunction. LED 1, LED 2, LED 3, LED 4 : Flashing
|
E7
|
EEPROM malfunction. LED 1, LED 2 : Flashing
|
E8
|
Water-level alarm malfunction. LED 4 Alarm: Flashing
|
If one of the following
malfunctions occur, stop operation, shut off the power, and contact with your
dealer.
- The
operation lamp is flashing rapidly (5Hz). This lamp is still flashing
rapidly after turn off the power and turn on again.
- Remote
controller receives malfunction or the button does not work well.
- A
safety device such as a fuse, a breaker frequently actuates.
- Obstacles
and water enter the unit.
- Water
leaks from indoor unit.
- Other malfunctions.
Troubleshooting
Symptoms: Unit
does not start
Causes:
- Power
failure.
- Power
switch is off.
- Fuse
of power switch may have burned.
- Batteries of remote controller exhausted or
other problem of controller.
Solution:
- Wait
for the comeback of power.
- Switch
on the power.
- Replace
the fuse.
- Replace the batteries or check the
controller.
Symptoms: Units
start or stop frequently
Causes:
- Refrigerant
is too little or too much.
- Air
or no concreting gas in the refrigerating circuit.
- Compressor
is malfunction.
- Voltage
is too high or too low.
- System circuit is blocked.
Solution:
- Check
leakage, and rightly recharge refrigerant.
- Vacuum
and recharge refrigerant.
- Maintenance
or change compressor.
- Install
manostat.
- Find reasons and solution.
Symptoms: Low
cooling effect
Causes:
- Outdoor
unit and indoor unit heat exchanger is dirty.
- The
air filter is dirty.
- Inlet/outlet
of indoor/outdoor units is blocked.
- Doors
and windows are open
- Sunlight
directly shine.
- Too
much heat resource.
- Outdoor
temp. is too high.
- Leakage of refrigerant or lack of
refrigerant.
Solution:
- Clean
the heat exchanger.
- Clean
the air filter.
- Eliminate
all dirties and make air smooth.
- Close
doors and windows.
- Make
curtains in order to shelter from sunshine.
- Reduce
heat source.
- AC
cooling capacity reduces (normal).
- Check leakage and rightly recharge
refrigerant.