Koppel Super Inverter AC Error Codes;


Koppel Air Conditioner Error Codes

Koppel Super Inverter AC Error Codes;
Koppel Air Conditioner Error Codes
Error Code
Problem
E0
Indoor unit EEPROM parameter error
E1
Indoor / outdoor units communication error
E2
Zero-crossing signal error
E3
Indoor fan speed has been out of control
E4
Open circuit or short circuit of indoor room temperature T1
E5
Open circuit or short circuit of evaporator coil temperature T2 sensor
EC
Refrigerant Leakage Detection
F1
Open circuit or short circuit of outdoor ambient T4 temperature sensor
F2
Open circuit or short circuit of condenser coil temperature T3 sensor
F3
Open circuit or short circuit of compressor discharge T5 temperature sensor
EEPROM parameter error diagnosis and solution E0/F4:

EEPROM parameter error diagnosis and solution E0/F4
Error Signals On The Display
In case of error, the display on the indoor unit shown the following error codes
Error Code: E 1
RUN lamp: flashes once
Description of the trouble: The fault of indoor temperature sensor
Error Code: E 2
RUN lamp: flashes twice
Description of the trouble: The fault of indoor pipe temperature sensor
Error Code: E 6
RUN lamp: flashes 6 times
Description of the trouble: Malfunction of indoor fan motor.


Koppel Super Inverter AC Error Codes

Koppel AC Troubleshooting

Malfunction: The appliance does not operate 
Possible Causes:
  1. Power failure/plug pulled out
  2. Damaged indoor/outdoor unit fan motor
  3. Faulty compressor thermomagnetic circuit breaker
  4. Faulty protective device or fuses.
  5. Loose connections or plug pulled out
  6. It sometimes stops operating to protect the appliance.
  7. Voltage higher or lower than the voltage range
  8. Active TIMER-ON function
  9. Damaged electronic control board
Malfunction:  Strange odour
Possible Causes: Air filter dirty
Malfunction:  Noise of running water
Possible Causes: Back flow of liquid in the refrigerant circulation
Malfunction:  A fine mist comes from the air outlet
Possible Causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes
Malfunction:  A strange noise can be heard
Possible Causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.
Malfunction:  Insufficient airflow, either hot or cold
Possible Causes:
  • Inappropriate temperature setting..
  • Air inlet or outlet of indoor or outdoor unit has been blocked.
  • Air filter is blocked.
  • Fan speed set at minimum.
  • Other sources of heat in the room.
  • No refrigerant


Koppel Air Conditioner Remote Control
Malfunction:  The appliance does not respond to commands



voltas AC unlock passwords