Galanz AC Error
Codes
F6: PG motor faults
F7: Indoor TEMP sensor faults
F8: Indoor coil pipe TEMP sensor faults
F9: Outdoor coil pipe TEMP sensor faults
Error Codes
|
Trouble
|
F1
|
Heat overloading protector
|
F2
|
Cool freeze protector
|
F3
|
Instantaneous power cut
|
F4
|
direct current fan motor no feedback
|
1F
|
cool overloading protector
|
2F
|
exhaust overheating protector
|
3F
|
over or not enough pressure protector
|
4F
|
over-current protector
|
5F
|
IPM protector
|
6F
|
defrost state
|
7F
|
direct current compressor drive exceptional
|
8F
|
direct current compressor cannt start
|
E1: The trouble of indoor unit room temperature sensor.
E2: The trouble of unit pipe temperature sensor. indoor
E3: The trouble of PG motor
E5: The trouble of bad communication of indoor unit and outdoor unit.
E6: The EEPRO of indoor unit error
1E: The trouble of outdoor unit pipe temperature sensor
3E: The trouble of exhaust sensor
4E: The EEPRO of indoor unit error
8E: The trouble of PFC.
Galanz Ac Error Codes And Troubleshooting
Operation of air conditioner: Fan speed setting is not allowed in AUTO or
DRY modeExplanation: The speed of the indoor fan is set to low in DRY mode. Fan speed of 3 steps is selected automatically in AUTO mode
Operation of air conditioner: Compressor stops operation intermittently in DRY mode
Explanation: Compressor operation is automatically controlled in DRY mode depending on the room temperature and humidity
Operation of air conditioner: Compressor of the outdoor unit is operating although it is turned off in HEAT mode
Explanation: When the unit is turned off while de-ice is activated, the compressor continues operation for up to 10 minutes (maximum) until the deice is completed
Operation of air conditioner: Timer indicator lamp lights up and the air conditioner does not operate
Explanation: Timer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled
Operation of air conditioner: The compressor and indoor fan stop intermittently in HEAT mode
Explanation: The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in HEAT mode
Operation of air conditioner: Indoor fan and outdoor fan stop intermittently in HEAT mode
Explanation: The compressor operates in a reverse cycle to remove exterior ice in HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heat operation
Operation of air conditioner: The compressor stops intermittently in COOL mode or DRY mode, and fan speed of the indoor unit decreases