Friedrich Multi Zone Air Conditioner


Friedrich Multi Zone Air Conditioner
Error code meaning
Indoor error


00 no error


01 indoor room themster error


02 Indoor in-piping sensor error


03 remote controller error


04 drain pump error


05 Communal error within and outside


06 indoor out-piping sensor error


07 Different Mode Operation


09 EEPROM even error check


10 Indoor BLDC Fan Lock
Outdoor error


21 DC Peak (IPM Error) – Over rated current off


22 CT2 (Max CT) 2 times – input of current off


23 DC Link Low Voltage. 2 times – DC link voltage is below 140Vdc off


24 L_P / H_P Switch – Low / High Press Switch Open Close


25 low voltage / over voltage – abnormal AC voltage input off


26 DC Compressor Status Error – Compressor Start Fall Collapse Error


27 PSC / PFC error – inverter PCB input current is over100A (peak) for 2us off


28 DC Link High Voltage – Closed


29 over current comp – inverter compressor turned off


32 D-Pipe High (INV) – Off Off


40 CT sensor (short/open) – CT circuit malfunction


41 INV. D-Pipe Threshold – Open / Short Off


44 Outdoor Air Threshold – Open / Short Off


45 Cond. Pipe Th fault – Open / Short Off


46 suction pipe fault – short/open off


51 Capacity of over 5times – over combination off


52 Signal error (DSP board <-> main board) – Communication poor shutdown


53 signal error (indoor <-> outdoor) – communication poor shutdown
Check error 60 Error – Check even missmatching


61 Cond. Pipe Th High – Cond. Temporary. Drunk


62 Heat Sink Th High-Heat Temp. Drunk


65 Heat Sink Threshold – Open / Short Off


67 Outdoor BLDC Fan Lock – Outdoor Fan Is Not Running Off


73 PFC Fault Error (S / W) – Overall Outdoor Unit PFC