Friedrich AC Error Codes| Troubleshooting
The Frederich Smart Center constantly monitoring the operation of the PT-AC unit and will store the service code if certain conditions are witnessed. In some cases the unit may take action and shut down the unit until the conditions are corrected.
PTAC – PD Series
Packaged Terminal Air Conditioner
Packaged Terminal Heat Pumps
Error code problem
E1 high pressure system protection
E2 antifreezing protection
F0 in refrigerant defects
E4 High discharge temperature protection of compressor
E5 Overcrout Protection
E6 communication malfunction


E8 High Temperature Resistant Protection


EE EEPROM Malfunction


EU limit / freq-uency reduction due to high temperature of module


C5 jumper cap malfunction protection
Foam collecting refrigerant


F1 indoor ambient temperature sensor is open / small circuit


F2 indoor evaporator temperature sensor is open / small circulated


F3 outdoor ambient temperature sensor is open / small circulated


F4 outdoor condenser temperature sensor is open / small circulated


F5 outdoor discharge temperature sensor is open / small circulated


F6 limit / decrease freq-uency due to over lode


F8 freq-uency decrease due to overcrack


F9 Reduction in freq-uency of due to high air discharge


FH limit / decrease freq-uency due to antifreezing
PH voltage too high for DC bus bar


DC bus bar PL voltage is too low


P0 compressor minimum freq-uency in test state


P1 compressor rated freq-uency at test stage


P2 compressor maximum freq-uency in test state


P3 compressor intermediate freq-uency in test state


P5 Overcrack protection of phase current for compressor
Capacitor PU charging fault


P7 module temperature sensor circuit malfunction


P8 Module High Temperature Protection


H0 freq-uency of decreases due to high temperature resistor during heating operation


H1 Defrosting


H2 static surrender protection


H3 over lode protection for compressor


H4 system is abnormal


H5 IPM Security


H6 internal motor (fan motor) does not operate


H7 Desynchronizing of Compressor


HC PFC Security


L3 Outdoor DC Fan Motor Malfunction


L9 Power Protection


LP does not match indoor unit and outdoor unit


LC failure startup


U1 malfunction of phase current detection circuit for compressor


U3 malfunction of voltage dropping for DC bus bar


U5 malfunction current detection of complete units


U7 four-way valve is abnormal


U9 Zerocrossing Outdoor Unit Malfunction
Digital Control Diagnostics and Test Mode


Error Code: 02
Code Translation: Extremely low voltage conditions exist <198V for 230V units and <239V for 265V units
Action taken by the unit: shutdown unit. Display error code and flash. Power is restored once the voltage is increased for the normal level system
Possible reasons:
Supply insufficient power supply
 Defector§
Use Blown Fuse


Error Code: 03
Code Translation: Return air thermistor sensor open or short circuit
Action taken by the unit: set the return air sensor = 75 ° F. Optional flash set point and error code. Quit running unit
Possible Cause: Defective sensor


Error Code: 04
Code translation: Indoor coil thermistor sensor open or short circuit
Action taken by the unit: Set ID coil temp = 40 ° F. Optional flash set point and error code. Quit running unit
Possible Cause: Defective sensor


Error Code: 05
Code Translation: Outdoor coil thermistor sensor open or short circuit
Action taken by the unit: setaud coil temp = 20 ° F. Optional flash set point and error code. Automatically change to electric heat mode only. Quit running unit
Possible Cause: Defective sensor


Error Code: 06
Code Translation: If O.D. Coil temperature> 175 deg F for 2 consecutive minutes. (Heat pump model only)
Action taken by the unit: optional flash set point and error code. Shut down unit for 5 minutes, then try again 2 times, if it fails for the 3rd time, close the unit.
Possible reasons:
Coil Dirty Coil
Failure Fan Motor Malfunction
 Restricted air flow§
. Non-condensation in refrigeration system


Error Code: 07
Code translation: ID coil temperature <30 deg for 2 consecutive minutes
Action taken by the unit: optional flash set point and error code. The compressor remains closed until the indoor coil thermistor reaches 45 ° F, and then continue operating the fan, activating the compressor. However, the compressor must still wait for a lockout time of 180 to 240 seconds
Possible reasons:
Filters Dirty Filters
Coil Dirty Coil
Failure Fan Motor Malfunction
 Restricted airflow§
 Improper refrigerant charge§
. Restriction in refrigerant circuit


Error Code: 08
Code translation: if unit cycle (heat or cold demand)> 9 times per hour
Action taken by the unit: optional flash set point and error code. Keep unit running
Possible reasons:
 Unit§ Maintenance
 Low load§ conditions


Error Code: 09
Code translation: if unit cycle (heat or cold demand) <3 times per hour
Action taken by the unit: optional flash set point and error code. Keep unit running
Possible reasons:
Un unit underestimated
 High Load§ Conditions


Error Code: 10
Code Translation: Room Freeze Protection Trigger
Action taken by the unit: optional flash set point and error code. Keep unit running
Possible reasons: room temperature drops below 40 ° F