Daikin AC Error
Codes
- Split AC Error Codes
- L Series AC Error Codes
- Multi AC Error Codes
- VRV IV 4 Error Codes
- VRV III 3 Error Codes
Error Codes
|
Problem
|
00
|
|
UA
|
Indoor-outdoor Unit Combination Fault
|
U0
|
Refrigerant Shortage
|
U2
|
Drop Voltage Or Main Circuit Overvoltage
|
U4
|
Failure Of Transmission (Between Indoor Unit And Outdoor
Unit)
|
A1
|
Indoor Pcb Defectiveness
|
A5
|
High-Pressure Control Or Freeze-up Protector
|
A6
|
Fan Motor Fault
|
C4
|
Faulty Heat Exchanger Temperature Sensor
|
C9
|
Faulty Suction Air Temperature Sensor
|
2- Daikin L Series AC Error Codes:
Error Codes
|
Meaning
|
System Error Codes
|
|
00
|
|
U0
|
U0
|
U2
|
Low-voltage detection or over-voltage detection
|
U4
|
Signal transmission error (between indoor unit and outdoor
unit)
|
UA
|
Unspecified voltage (between indoor unit and outdoor unit)
|
Indoor Unit Error Codes
|
|
A1
|
Indoor unit PCB abnormality
|
A5
|
Freeze-up protection control or heating peak-cut control
|
A6
|
Fan motor or related abnormality
|
C4
|
Indoor heat exchanger thermistor or related abnormality
|
C9
|
Room temperature thermistor or related abnormality
|
Outdoor Unit Error Codes
|
|
E1
|
Outdoor unit PCB abnormality
|
E5
|
OL activation (compressor overload)
|
E6
|
Compressor lock
|
E7
|
DC fan lock
|
E8
|
Input overcurrent detection
|
EA
|
FourWay valve abnormality
|
F3
|
Discharge pipe temperature control
|
F6
|
High-pressure control in cooling
|
H0
|
Compressor system sensor abnormality
|
H6
|
Position sensor abnormality
|
H8
|
DC voltage / current sensor abnormality - CT or related
abnormality
|
H9
|
Outdoor temperature thermistor or related abnormality
|
J3
|
Discharge pipe thermistor or related abnormality
|
J6
|
Outdoor heat exchanger thermistor or related abnormality
|
L3
|
Electrical box temperature rise
|
L4
|
Radiation fin temperature rise
|
L5
|
Output overcurrent detection
|
P4
|
Radiation fin thermistor or related abnormality
|
U7
|
Signal transmission error on outdoor unit PCB
|
Remote Controller Display: A1
Supposed Causes:
- When We This Error The Problem Is interconnected Is Wrong models
- Defective indoor unit PCB After See This Error
- Disconnection of connector
- Reduction of power supply voltage
Supposed Causes:
- When You See This Error So You Ac Is Short-circuited air
- Clogged air filter of the indoor unit When We See A5 Error
- After See This Error That Means Dust accumulation on the indoor heat exchanger
- Defective indoor heat exchanger thermistor
- When This happens Your Ac Have Defective indoor unit PCB
Supposed Causes:
- After See This Error That Means Layer short inside the fan motor winding
- Breaking of wire inside the fan motor
- Breaking of the fan motor lead wires
- When On Display Is A6 Means Defective capacitor of the fan motor
- After Again And Again See This Error Maybe Defective indoor unit PCB
Supposed Causes:
- Disconnection of connector
- thermistor Defective
- Defective indoor unit PCB
Solve
Daikin Ac Troubleshooting
Remote Controller Display: U0Supposed Causes:
- Disconnection of the discharge pipe thermistor, indoor or outdoor heat exchanger thermistor, room or outdoor temperature thermistor
- Closed stop valve
- Refrigerant shortage (refrigerant leakage)
- Poor compression performance of compressor
- Defective electronic expansion valve
Supposed Causes:
- Supply voltage is not as specified.
- DC voltage detection circuit
- e over-voltage detection circuit
- PAM control part
- Disconnection of compressor harness
- When See U2 That Means Maybe Noise Problem
- Momentary fall of voltage
- Momentary power failure
- Defective indoor unit PCB
Supposed Causes:
- First Cause Of This Error Is Wiring error
- Breaking of the connection wires between the indoor and outdoor units (wire No. 3)
- outdoor unit PCB Is Faulty
- Defective indoor unit PCB
- Disturbed power supply waveform
Remote
Controller Display: U7
Supposed Causes: That Means Defective Is outdoor unit PCBRemote Controller Display: UA
Supposed Causes:
- Wrong models interconnected
- wiring of connecting wires Is Wrong
- Wrong indoor unit PCB or outdoor unit PCB mounted
- Defective indoor unit PCB
- Defective outdoor unit PCB
Remote Controller Display: E1
Supposed Causes:- outdoor unit PCB Defective
- Broken harness between PCBs
- Noise
- Momentary fall of voltage
- Momentary power failure, etc
Supposed Causes:
- Discharge pipe thermistor
- Defective electronic expansion valve or coil
- When You See This Error That Means FourWay valve or coil Is Faulty
- After Again See This Error Defective outdoor unit PCB
- Refrigerant shortage Problem When We See This
- Water mixed in refrigerant
- Defective stop valve
- Compressor locked After This Error Show On Display
- When We See E6 Error Compressor harness disconnected
Supposed Causes:
- Foreign matter stuck in the fan
- When You See This E7 That Means Defective fan motor
- outdoor unit PCB Is Faulty After We See This Error
Supposed Causes:
- After See This Error On Display Means Outdoor temperature is out of operation range.
- Wen We See This Error Means Defective compressor
- power module Is Faulty When We See This
- Faulty Is outdoor unit PCB
- Short circuit
Supposed Causes:
- Disconnection of fourway valve coil
- Defective fourway valve, coil, or harness
- After See This Error On Diplay MAybe outdoor unit PCB
- thermistor Is Faulty
- Refrigerant shortage
- Water mixed in refrigerant When You See This
- After Again See This Error That Means stop valve Is Not Good
Remote Controller Display: F3
Supposed Causes:- When See This Error Maybe discharge pipe thermistor
- Fault In electronic expansion valve or coil
- When See This Is Error Means Refrigerant shortage
- Defective fourway valve
- Water mixed in refrigerant
- stop valve Is Faulty
- PCB Of Outdoor Unit Is Defective
Supposed Causes:
- The installation space is not large enough.
- Dirty outdoor heat exchanger
- outdoor fan motor
- stop valve
- electronic expansion valve or coil
- outdoor heat exchanger thermistor
- outdoor unit PCB
Supposed Causes:
- Broken or disconnected harness
- outdoor unit PCB Is Faulty
Supposed Causes:
- Disconnection of the compressor relay cable
- compressor Not Good
- teoutdoor unit PCB Is not Good
- Start-up failure caused by the closed stop valve
- Input voltage is outside the specified range.
Supposed Causes: outdoor unit PCB Is Not Working
Remote Controller Display: H9, J3, J6, P4
Supposed Causes:
- Disconnection of the connector for the thermistor
- thermistor corresponding to the error code
- heat exchanger thermistor in the case of J3 error
- outdoor unit PCB
Supposed Causes:
- outdoor fan motor
- When Again See This That Means Short circuit
- Radiation fin thermistor Is Faulty When You See This
- Disconnection of connector
- PCB Of Outdoor Unit Is Faulty
Remote Controller Display: L4
Supposed Causes:- When We L4 Error That Means fan motor Of Outdoor Unit Is Faulty
- And The Second Issue Is Short circuit
- And The Another One is Defective radiation fin thermistor
- When See This Error 4th Issue Is Disconnection of connector
- After Face L4 Maybe outdoor unit PCB
- When You See L4 Is On Display Maybe That Means Silicon grease is not applied properly on the radiation fin after replacing the outdoor unit PCB.
Supposed Causes:
- When L5 On Display That Means Poor installation condition
- And Second One Is Closed stop valve
- After See L5 Maybe power module Is Faulty
- If We Face Again That Means Wrong internal wiring
- L5 Error Other Means Abnormal power supply voltage
- When You See Again This Problem In outdoor unit PCB
- After Again And Again See This Error Last Means Your compressor Is Not Working
- When the timer cancel button is held down for 5 seconds, 00 is displayed on the temperature display screen.
- After That Press the timer cancel button repeatedly until a long beep sounds.
3-Daikin
Multi-Split Type AC Error Codes:
Daikin’s multi-split type air conditioning systems offer superior
performance, energy-efficiency, and comfort in stylish solutions conforming to
all interior spaces and lifestyles.An extensive product lineup utilizes Daikin technology for lower costs and environmental impact. Advanced inverter and heat pump technologies achieve greater efficiency and energy-savings at lower costs.
A broad array of models allows the perfect match of style and performance to any interior space.
2/3/4MXS-G/J Series/Heat Pump
Error Codes
|
Problem
|
00
|
|
UA
|
Indoor-Outdoor Unit Combination Fault
|
U0
|
Refrigerant Shortage
|
U2
|
Drop Voltage or Main Circuit Overvoltage
|
U4
|
Failure Of Transmission (Between Indoor Unit and Outdoor
Unit)
|
A1
|
Indoor PCB Defectiveness
|
A5
|
High Pressure Control or Freeze-up Protector
|
A6
|
Fan Motor Fault
|
C4
|
Faulty Heat Exchanger Temperature Sensor
|
C9
|
Faulty Suction Air Temperature Sensor
|
EA
|
Cooling-Heating Switching Error
|
E1
|
Circuit Board Fault
|
E5
|
OL Started
|
E6
|
Faulty Compressor Start Up
|
E7
|
DC Fan Motor Fault
|
E8
|
Overcurrent Input
|
F3
|
High Temperature Discharge Pipe Control
|
F6
|
High Pressure Control (In Cooling)
|
H0
|
Sensor Fault
|
H6
|
Operation Halt Due To Faulty Position Detection Sensor
|
H8
|
DC Current Sensor Fault
|
H9
|
Faulty Suction Air Temperature Sensor
|
J3
|
Faulty Discharge Pipe Temperature Sensor
|
J6
|
Faulty Heat Exchanger Temperature Sensor
|
L3
|
Electrical Parts Heat Fault
|
L4
|
High Temperature At Inverter Circuit Heatsink
|
L5
|
Output Overcurrent
|
P4
|
Faulty Inverter Circuit Heatsink Temperature Sensor
|