Carrier High Wall Split-Type AC Error Codes


Carrier High Wall Split-Type AC Error Codes

The electronic printed circuit board in the indoor unit is equipped with smart self diagnostic function which automatically stops the operation of the air conditioner in case of a malfunction.
– Self-diagnostic function is the key for success of air conditioner operation.
– The printed circuit boards existing inside the indoor unit are equipped with self-diagnostic function to detect malfunction and automatically stops the operation at the air conditioner.
– Once a malfunction is detected, the lamps of the indoor unit be as per the below tables :


Error Code: E1 
Malfunction Reason: Electronic Control PCB· ( EEROM defect )
Error Code: E2
Malfunction Reason: Zero-crossing signal detection error
Error Code: E3
Malfunction Reason: Indoor Fan speed out of control
Error Code: E5 
Malfunction Reason: Return Air Sensor (open circuit or short circuit)
Error Code: E6 
Malfunction Reason: Indoor Coil Sensor ( open circuit or short circuit )
Error Code: E7 
Malfunction Reason: Outdoor Coil Sensor ( open circuit or short circuit )
Error Code: EC 
Malfunction Reason: Refrigerant leak

NOTES
1- Prior to the malfunction repair, disconnect the electrical mains supply by moving the circuit breaker to OFF position.
2- After repairing the malfunction:
2-1 connect the electrical main supply by moving the circuit breaker to ON position
2-2 operate the air conditioner by using the wireless remote control.